![Bose controlcenter CC-1 Installation And Operation Manual Download Page 22](http://html1.mh-extra.com/html/bose/controlcenter-cc-1/controlcenter-cc-1_installation-and-operation-manual_2791598022.webp)
CC-2 Installation Guide
pro.Bose.com
22 English
1
2
3
4
5
6
7
8
Controller #1
1
0
1
0
1
0
0
0
IZA/ZA/DSP #2
0
1
0
1
0
1
0
0
DXA 2120 #2
0
1
0
1
1
0
0
0
Connect two ganged CC-2 zone controllers to FreeSpace® amplifier model IZA 2120-HZ or
DXA 2120, or any ControlSpace processor.
B
A
FreeSpace IZA 2120-HZ
FreeSpace DXA 2120
ControlSpace Processor (Any)
B
A
CC-2 Zone
Controller #1
CC-2 Zone
Controller #2
CAT 5 cable
609 m (2000 ft) max total length
RJ-45 (Main)
on CC-2 #1
RJ-45 (Chain)
on CC-2 #2
FreeSpace
IZA 2120-HZ
Wiring with
Optional CAT 5
Daisy-Chain
Wiring if Using
Two Home Runs
to IZA 2120-HZ
VOL #2
A/B #2
PWR #2
RJ-45
RJ-45 (Main)
on CC-2
Any ESP
Wiring with
Optional CAT 5
Daisy-Chain
Wiring if Using
Two Home Runs
to DXA 2120
RJ-45 (Chain)
on CC-2 #2
RJ-45 (Main)
on CC-2 #1
FreeSpace
DXA 2120
PWR
A/B_2
VOL_2
DIP
ON
1 2 3 4 5 6 7 8
CC-2 Zone Controller #1
DIP
ON
1 2 3 4 5 6 7 8
CC-2 Zone Controller #2
DIP
ON
1 2 3 4 5 6 7 8
CC-2 Zone Controller #2
Configure two ganged CC-2 zone controllers using the
following DIP switch settings:
Pin-to-Remote Connection Diagrams
IZA/ZA/DSP
DXA 2120