Displays
6 720 644 143 (2010/09)
16 Displays
The display shows the following (table 25 and 26):
Value displayed
Description
Range
Number or letter,
dot followed by
letter
Service function
(
Æ
table 15/ 16,
page 44)
Letter followed
by number or
letter
Fault code flashes
(
Æ
table 27, page 67)
Two numbers
Decimal figure, e.g.
flow temperature
00..99
U followed by
0..9
Decimal figure;100..109
is displayed as U 0..U9
0..109
One number
(displayed for
longer) followed
twice by two
numbers
(displayed
briefly)
Decimal figure (three
digits);
first digit is shown
alternating with the
two last digits (e.g.
1...69..69 for 169)
0..999
Two dashes
followed by two
pairs of numbers
Boiler coding card
number;
Value is shown in three
stages:
1. Two dashes
2. First two numbers
3. Last two numbers
(e.g.: -- ..10..04)
1000
...
9999
Two letters
followed by two
pairs of numbers
Version number;
Value is shown is three
stages:
1. First two letters
2. First two numbers
3. Last two numbers
(e.g.: CF 10 20)
Table 25 Displays
Special
display
Description
Acknowledge by pressing any key (except
reset).
Acknowledge by pressing two keys
simultaneously
Acknowledge by pressing and holding
for more than 3 seconds (Save function).
The display alternately shows the flow
temperature and
. The appliance
operates for 15 minutes at the minimum
rated output.
The display shows the flow temperature
alternating with
. The appliance works
with the set maximum rated output in
heating mode,
Æ
service function
1.A
.
The display alternately shows the flow
temperature and
. The appliance
operates for 15 minutes at the maximum
rated output.
Ventilation function is enabled, see
service function
2.C.
The display shows the flow temperature
alternating with
. The trap filling
program is enabled,
Æ
service function
4.F
.
The display shows the flow temperature
alternating with
: the set inspection
interval has elapsed,
Æ
service function
5.A
.
The display alternately shows the flow
temperature and
. The heating circuit
pump is blocked.
The display shows the flow temperature
alternating with
. The temperature
gradient limiter is enabled. Excessive
flow temperature increase: heating mode
is suspended for two minutes.
Table 26 Special displays