Electrical connections
6 720 644 143 (2010/09)
B
To provide anti-splash protection (IP), always cut
cable grip to fit cable diameter.
Fig. 30
B
Feed cable through cable grip and connect as
appropriate.
B
Secure cable in cable grommet by means of cable
grip.
7.2.1
Connecting the heating controller or remote
control units
Only operate this appliance with a Bosch controller.
Heating controller FW 100 can also be mounted right at
the front in the Heatronic 3.
For installation and electrical connection, see the
relevant installation instructions.
7.2.2
Connecting the DHW cylinder
Cylinders with Bosch cylinder temperature sensors are
connected directly to the appliance PCB.
B
Snap off the plastic tongue.
B
Insert the cylinder temperature sensor lead.
B
Plug the connector into the PCB.
Fig. 31
7.2.3
Connecting temperature limiter TB 1 from the
flow of an underfloor heating system
Only for underfloor heating systems connected directly
to the appliance.
Fig. 32
If the temperature limiter trips, central heating and DHW
modes are interrupted.