Commissioning
|
37
6 720 644 143 (2010/09)
8.3
Starting the central heating
The maximum flow temperature can be matched to the
heating system by the flow temperature controller. The
current flow temperature is shown on the display.
B
Turn flow temperature controller
to adjust the
maximum flow temperature.
Fig. 35
When the burner is firing, the green indicator lamp
lights up.
8.4
Setting the heating control unit
Fig. 36
8.5
After commissioning
B
Check the gas supply pressure (
Æ
page 52).
B
Check the condensate drain to ensure that
condensate runs out. If that is not the case, switch the
main switch off and on again. This activates the
siphon filling program (
Æ
page 48). Repeat this
procedure several times until condensate starts
running out.
B
Record the settings in the commissioning report
(
Æ
page 74).
B
Affix the “Heatronic settings” label to the casing in a
clearly visible position (
Æ
page 43).
Setting on flow
tem-perature
controller
Flow
temperature
Sample
application
1
Approx. 35 °C
2
Approx. 43 °C
3
Approx. 50 °C
Underfloor
heating system
4
Approx. 60 °C
5
Approx. 67 °C
6
Approx. 75 °C
Radiator
heating system
max.
Approx. 90 °C
Convector
heating system
Table 12
With underfloor heating systems, take care
to observe the maximum permissible CH
flow temperatures.
eco
reset
6 720 644 143-27.1O
max
1
2
3
4
5
6
max
1
2
3
4
e
6
min
Follow the operating instructions for the
heating controller used. Those instructions
will tell you
B
how to set the operating mode and the
heating curve for weather-dependent
controllers,
B
how to adjust the room temperature,
B
how to heat economically and save
energy.
9
12 h
15
18
21
24 h
3
6
6 720 612 660-07.2O