1.1 

In the documentation

1.1.1 

Warning notices - Structure and meaning

Warning notices warn of dangers to the user or people 
in the vicinity. Warning notices also indicate the 
consequences of the hazard as well as preventive action. 
Warning notices have the following structure:

Warning 
symbol

KEY WORD – Nature and source of hazard!

Consequences of hazard in the event of 
failure to observe action and information 
given.

 

Hazard prevention action and information.

The key word indicates the likelihood of occurrence and 
the severity of the hazard in the event of non-observance:

Key word

Probability of 
 occurrence

Severity of danger if 
instructions not observed

DANGER

Immediate

 impending 

danger

Death

 or 

severe 

injury

WARNING

Possible

 impending

danger

Death

 or 

severe 

injury

CAUTION

Possible 

dangerous

 

situation

Minor

 injury

1.1.2 

Symbols in this documentation

Symbol Designation

Explanation

!

Attention

Warns about possible property damage.

i

Information

Practical hints and other  
useful information.

1.
2.

Multi-step  
operation

Instruction consisting of several steps.

e

One-step  
operation

Instruction consisting of one step.

 

Intermediate 
result

An instruction produces a visible 
intermediate result.

"

Final result

There is a visible final result on 
completion of the instruction.

DANGER – Exposure of live parts on 
opening the VLS 3130!

Risk of (fatal) injury or heart failure 
from electric shocks on contact with live 
components (e.g. master switch, printed 
circuit boards). 

 

Work on electrical installations or 
equipment is only to be performed by 
qualified electricians or trained personnel 
under the guidance and supervision of an 
electrician. 

 

Disconnect the VLS 3130 from the mains 
before opening.

Disposal

Dispose of used electrical and electronic 
devices, including cables, accessories and 
batteries, separately from household waste.

1.2 

On the product

 

!

Observe all warning notices on products and ensure 
they remain legible.

The transporting of persons on the lifting 
tables or in the vehicle is prohibited.

Notes on load distribution

The load center must be within the designated area.

Quick user guide

 

Safety instructions

 

Operation

 

Controls

 

Maintenance work

 

Load distribution

 

Approach direction

Summary of Contents for VLS 3130

Page 1: ...ruzioni originali Ponte sollevatore a pantografo a corsa corta sv Bruksanvisning i original Låglyftande billyft av saxmodell nl Oorspronkelijke gebruiksaanwijzing Hefplatform met korte hefscharen pt Manual original Plataforma elevatória tipo tesoura de pequeno curso pl Instrukcją oryginalną cs Původní návod k používání tr Orijinal işletme talimatı zh 原始的指南 Podnośnik krótkonożycowy Nízkozdvižná nůž...

Page 2: ... 26 5 8 3 Lifting mechanism 26 5 8 4 Access ramps 26 5 8 5 Operating unit 27 5 8 6 Rotary reversing switch 27 5 9 Safety features 27 6 Operation 28 6 1 Essential points for operation 28 6 2 Preparation 28 6 3 Vehicle positioning 28 6 4 Lifting the vehicle 29 6 5 During work on vehicle 29 6 6 Lowering the vehicle 30 6 7 Driving the vehicle off 30 6 8 Deactivation 30 7 Using the mobile set 31 8 Note...

Page 3: ...tion Practical hints and other useful information 1 2 Multi step operation Instruction consisting of several steps e One step operation Instruction consisting of one step Intermediate result An instruction produces a visible intermediate result Final result There is a visible final result on completion of the instruction DANGER Exposure of live parts on opening the VLS 3130 Risk of fatal injury or...

Page 4: ... up Safety measures The lifting platform is only ever to be employed for the intended purpose Carefully study and heed all the information given in Section 6 1 Observe the warning notices for operation Section 6 Use of the product constitutes acceptance of the following conditions Copyright The enclosed instructions are the property of Robert Bosch GmbH or its suppliers and are protected against r...

Page 5: ...dge of lifting platforms and who is familiar enough with the pertinent national regulations accident prevention regulations and generally acknowledged rules of engineering e g BG rules DIN Standards VDE provisions the technical regulations of other European Union member states or other parties to the agreement on the European economic area to be able to assess the safe operating condition of lifti...

Page 6: ...oved lifting platform VLS 3130 is intended solely for the following use Lifting passenger cars or motor vehicles with the aid of two lifting tables The limit values for the lifting platform s load bearing capacity and load distribution must be observed The following regulations must be observed when starting up and operating lifting platforms Rules for lifting platform operation BGR 500 Basic prin...

Page 7: ...dation following consultation with Bosch customer service or an authorized service agent Routing of the wiring to the installation location The user must provide fuse protection for the connection Routing of the compressed air connection to the installation location The user must install a service unit upstream of the connection i Refer also to the corresponding information in the commissioning in...

Page 8: ...d lowered via hydraulic cylinders 4 Each scissor mechanism carries a lifting table 2 which acts as the load bearing element 5 8 3 Lifting mechanism Two hydraulic cylinders are attached to each scissor strut When the hydraulic cylinders extend the scissors move up thereby raising the lifting table The synchronized movement of both sides is ensured as follows The scissor struts on both sides are con...

Page 9: ...atform must only be maintained and repaired by Bosch customer service or an authorized service agent with appropriate certification Always use genuine replacement parts The installation of parts from other manufacturers will render the type approval and any warranty claims invalid In particular the functioning of the following safety devices must be checked after any fault Safety feature Function ...

Page 10: ...witch is turned to OFF O Never use the lifting platform in the event of malfunction or component damage If the lifting platform malfunctions shut it down immediately secure it against unauthorized use and notify Bosch customer service or an authorized service outlet Lock the rotary reversing switch when the lifting platform is not in use 6 2 Preparation 1 Make sure that the lifting platform is con...

Page 11: ...ton is pressed 4 Raise the vehicle until its tires are off the ground 5 Stop the lifting table and check that the elastomer retainers are firmly affixed to the lifting points i If the vehicle is not stable lower the lifting platform and reposition the vehicle before raising it again 6 Continue raising the vehicle after ensuring its stability 7 Raise the lifting platform to the desired height or un...

Page 12: ...itch to lowering u and hold it in this position The lifting tables move downward as long as the button is pressed Lowering of the running rail is stopped automatically at a height of 300 mm foot protection safety level 3 Check the area beneath the running rail 4 If it is safe to do so press and hold the foot protection confirmation button 5 Turn the rotary reversing switch to lowering u again and ...

Page 13: ...ng rollers 2 Attachment point for draw bar 3 Draw bar with wheels 3 Fully lower the lifting platform The rotation of the front transverse bar presses the running rollers onto the ground The front end of the lifting platform rests on the running rollers Fig 8 Attachable running roller after lowering of lifting platform Transporting the lifting platform 1 Disconnect the mains plug of the operating u...

Page 14: ... platform has been exceeded Check the oil level Manually close the lowering valve Request customer service Lifting platform raises very slowly Vehicle too heavy Intake filter blocked Hydraulic system defective Check whether the permissible load bearing capacity of the lifting platform has been exceeded Clean intake filter service personnel Request customer service Lifting platform lowers too slowl...

Page 15: ...em component Order no Access ramp See spare parts list Hydraulic fluid 20 mm elastomer retainers x 4 1 692 872 361 60 mm elastomer retainers x 4 1 692 872 362 90 mm elastomer retainers x 4 1 692 872 363 9 5 Maintenance by the user The maintenance work described below must be performed by the user Prior to maintenance the platform must always be disconnected from the mains and secured to prevent un...

Page 16: ...ng 10 1 Temporary shutdown In the event of lengthy periods of non use Disconnect the VLS 3130 from the mains Lock the rotary reversing switch 10 2 Change of location If the VLS 3130 is passed on all the documentation included in the scope of delivery must be handed over together with the unit The VLS 3130 is only ever to be transported in the original or equivalent packaging Unplug the electrical ...

Page 17: ...Rated power 2 2 kW Control voltage 24 V AC Duty cycle S2 5 Min Protection rating IP 54 Protection class II 11 3 2 Hydraulic Property Value range Operating pressure 100 bar Tank volume 10 l Hydraulic fluid Type Purity level according to ISO 4406 Mineral oil in accordance with ISO 6743 4 Maximum 18 15 11 4 Electromagnetic compatibility EMC The VLS 3130 satisfies the requirements of the EMC directive...

Reviews: