VIP X1
| Installation and Operating Manual
EN | 77
Bosch Security Systems | 2006-12 | V2.5
Configuration using a Web browser
Scene too noisy
Activate this function if tampering associated with EMC interference (noisy
scene as the result of a strong interference signal in the vicinity of the video
lines), as an example, should trigger an alarm.
Reference check
You can save a reference image that is continuously compared with the current
video image. If the current video image in the marked areas differs from the ref-
erence image, an alarm is triggered. This allows you to detect tampering that
would otherwise not be detected, for example if the camera is turned.
– Click
Reference
to save the currently visible video image as a reference.
– Click
Select area
and select the areas in the reference image that are to be
monitored.
– Check the box
Reference check
to activate on-going matching. The stored
reference image is displayed in black and white below the current video
image, and the selected areas are marked in red.