Relay follows:
If required, select a specific event that will trigger the relay. The following events
are possible triggers:
❚
Off
Relay is not triggered by events
❚
Connection
Trigger whenever a connection is made
❚
Video alarm 1
Trigger by interrupting the video signal
❚
Motion alarm 1
Trigger by means of motion alarm as configured on the page
VCA
(see
page 73)
❚
Local input 1
Trigger by external alarm input 1
❚
Remote input 1
Trigger by remote station's switching contact (only if a connection exists)
Relay name:
You can assign a name for the relay here. The name is shown on the button next
to
Trigger relay
. The Livepage can also be configured to display the name
under the relay icon.
Trigger relay:
Click the button to trigger the relay manually (for testing or to operate a door