HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. To
limit connection to HTTPS, deactivate the HTTP port. To do this, activate the Off option.
HTTPS browser port
To limit browser access to encrypted connections, choose an HTTPS port from the list. The
standard HTTPS port is 443. Select the Off option to deactivate HTTPS ports and limit
connections to unencrypted ports.
The camera uses the TLS 1.0 protocol. Ensure that the browser has been configured to
support this protocol. Also ensure that Java application support is activated (in the Java Plug-
in Control Panel of the Windows Control Panel).
To limit connections to SSL encryption, set the Off option in the HTTP browser port, the RCP+
port, and Telnet support. This deactivates all unencrypted connections allowing connections
on the HTTPS port only.
Configure and activate encryption for media data (video, audio, metadata) on the Encryption
page.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on this port. To allow only
encrypted connections, set the Off option to deactivate the port.
Telnet support
Activating Telenet support allows unencrypted connections on this port. To allow only
encrypted connections, set the Off option to deactivate telnet support, making telnet
connections impossible.
Interface mode PoE
Select the type of Ethernet link for the interface for the camera “bound” to VIDEOJET connect
7000 (connected to the port labeled PoE on the PCBA of VIDEOJET connect 7000).
Depending on the device connected, it may be necessary to select a special operation type.
Options are:
–
Auto
–
10 Mbps HD (half duplex)
–
10 Mbps FD (full duplex)
–
100 Mbps HD (half duplex)
–
100 Mbps FD (full duplex)
Interface mode ETH 1
If necessary, select the type of Ethernet link for the interface for the device connected to the
port labeled ETH 1 on the PCBA of VIDEOJET connect 7000.
Depending on the device connected, it may be necessary to select a special operation type.
Options are:
–
Auto
–
10 Mbps HD (half duplex)
–
10 Mbps FD (full duplex)
–
100 Mbps HD (half duplex)
–
100 Mbps FD (full duplex)
Note: Do not select a baud rate for this port unless a device is connected to this port on
VIDEOJET connect 7000.
12.1.6
12.1.7
12.1.8
12.1.9
12.1.10
12.1.11
VIDEOJET connect 7000
Network | en
43
Bosch Security Systems
Operation Manual
2014.10 | 1.4 | F.01U.291.524
Summary of Contents for VIDEOJET connect 7000
Page 1: ...VIDEOJET connect 7000 VJC 7000 90 en Operation Manual ...
Page 2: ......
Page 58: ......
Page 59: ......