Online Measurement and Calibration | 13
Bosch Motorsport
Vehicle_Control_Unit_VCU_Manual
77 / 136
13.3 Online calibration of multipoint adjustment
channels
Example: measurement of wheel force
– Physical property ‘wheel force’ not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at wheel
Force at sensor
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter ‘Configuring a multipoint adjustment [
57]’.
2.
Download the configuration on the Vehicle Control Unit VCU. To connect the Vehicle
Control Unit VCU to RaceCon, see chapter ‘Setting up a new RaceCon Project’.
3.
Click on the desired channel in the Vehicle Control Unit VCU Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
Click to open
calibration
window
Analog and physical
value
5.
Click on ‘Calibrate adjustment points’ to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7.
Enter the physical value in the value column of the desired calibration point
(e.g. 745 N).
Summary of Contents for VCU
Page 1: ...Vehicle Control Unit VCU Manual Version 1 3 02 07 2020 ...
Page 90: ...14 Recording 90 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Page 133: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 133 136 ...
Page 134: ...134 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Page 135: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 135 136 ...