Lap Trigger | 16
Bosch Motorsport
Vehicle_Control_Unit_VCU_Manual
107 / 136
Channel
Function
Laptrigger_laptime_dls
Running laptime
Laptrigger_laptime_best_dls
Laptime of best lap
Laptrigger_laptimeold_dls
Laptime of last lap completed
Laptrigger_laptimeseg_dls
Segment time of last segment
Laptrigger_lapctr_dls
Number of completed laps
16.3.1 Time based retrigger protection
Trigger is locked for 5 s after main trigger was received.
To deactivate time based retrigger protection, set ‘Retrigger lock time’ to 0 ms.
Define settings for lap timing
(main trigger).
Define settings for sub trigger.
Not applicable with a GPS lap trigger.
5000ms
Main Trigger
16.3.2 Distance based retrigger protection
Trigger is locked until configured min distance (i.e. 80 % → 3200 m) of track distance (i.e.
4000 m) has been covered. To deactivate distance based retrigger protection, set min dis-
tance to 0 %.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
Summary of Contents for VCU