Temperature rating
+80 °C (+176 °F) or greater
Reference type
Belden 9259
Table 4.2: Video cable specifications
Input power cord
Cable type
3 x 18 AWG
Cable diameter (outer)
4.6 mm to 7.9 mm (0.18 in. to 0.31 in.)
Cable shape
Round
Conductors
3 or 2
Voltage rating
300 V
Certificating authority
UL/C.S.A., UL VW-1
Environmental
Outdoor rated
Temperature rating
+105° C (+221° F) or greater
Reference type
Belden 19509, 3-conductor; Northwire FSJT183-81K, 3-
conductor
Table 4.3: Power cord specifications for North America
Cable type
H05RN-F 3 G 0.75;
H05RN-F 3 G 1.00
Cable diameter (outer)
4.6 mm to 7.9 mm (0.18 in. to 0.31 in.)
Cable shape
Round
Conductors
3 or 2
Voltage rating
300 V
Certificating authority
VDE
Environmental
Outdoor rated
Reference type
Olflex rubber cable 1600 252; Olflex rubber cable 1600
253
Table 4.4: Power cord specifications for Europe
Lens control cable
Cable type
Jacketed multiconductor cable
Cable diameter (outer)
4.6 mm to 7.9 mm (0.18 in. to 0.31 in.)
Cable shape
Round
Cable shield
Overall
Conductors
4 and 8
4.2.2
4.2.3
UHI/UHO Series Camera Housing
Installation | en
15
Bosch Security Systems, Inc.
Operation Manual
2014.05 | 4.0 | F.01U.167.418
Summary of Contents for UHI Series