Installation
!
Caution!
Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National
Electrical Code
®
(NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1),
and all applicable local codes. Bosch Security Systems, Inc. accepts no liability for any
damages or losses caused by incorrect or improper installation.
!
Caution!
These units must be properly and securely mounted to a supporting structure capable of
sustaining the unit weight. Use care when selecting mounts or pan/tilts (not supplied) for
installation; the mounting surface and unit's weight should be carefully considered.
Camera requirements
The cameras to be built into the housing must meet the requirements specified below.
Ambient temperature
0 °C to +50 °C (+32 °F to +122 °F)
Power consumption
10 W (max)
Voltage for low voltage units
12 VAC to 28 VAC; +12 VDC to +30 VDC
Voltage for high voltage units
100 VAC to 240 VAC
Weight without lens
450 g max
Weight with lens
1 kg max
Temperature under operating conditions
-20 °C to +50 °C (-4 °F to +122 °F)
Table 4.1: Specifications for cameras
Cable requirements
Video transmission (coaxial)
Cable type
runs < 300m (1000 ft)
runs < 600m (2000 ft)
RG-59/U RG-11/U
Cable diameter (outer)
4.6 mm to 7.9 mm (0.18 in to 0.31 in)
Cable shape
Round
Cable shield
>93% braided copper
Center conductor
Stranded or solid copper
DC resistance
RG-59/U
RG-11/U
<15 ohm/1000 m <6 ohm/1000 m
Cable impedance
75 ohm
Certificating authority
UL
Environmental
Outdoor rated
4
4.1
4.2
4.2.1
14
en | Installation
UHI/UHO Series Camera Housing
2014.05 | 4.0 | F.01U.167.418
Operation Manual
Bosch Security Systems, Inc.
Summary of Contents for UHI Series
Page 1: ...UHI UHO Series Camera Housing UHx UHI UHO en Operation Manual ...
Page 2: ......
Page 34: ......
Page 35: ......