11. Turn the main function switch to the FLUSH
position. Allow the machine to operate for 30
seconds. See Figure 6.
See Figure 7
6. Locate the adapters as required for the ve-
hicle being tested. Refer to Transmission
Cooling System Service Tool Adapters on
page 17 for a complete list of adapters.
7. Connect the appropriate adapter(s) (J-35944-
201 shown as an example) to the supplied
TransFlow adapter J-45096-21. See Figure 2.
8. Repeat step 7 to build a second adapter as-
sembly if required.
Note: Most vehicle applications will require
two sets of adapter assemblies except those
vehicle applications that use J-45806 or
J-35944-440.
9. Connect the assembled adapters to the ve-
hicle’s T.O.C. supply and return lines at the
transmission. See Figure 3.
10. Connect the black supply hose and clear
waste hose to the vehicle cooler lines in the
reverse flow (backflush) direction. Refer
to bulletin #02-07-30-052 for T.O.C. flow
direction. See Figure 4 and 5.
Figure 3
Figure 4
Figure 5
Flow Test/Flush Operation contd.
pLEASE
WAIT
Figure 2
J-45096-21
J-35944-201
Supply
Hose
Waste
Hose
Supply
Hose
Figure 6