Specifications
TR1000 12 B – 6 720 876 017 (2017/08)
8
Connection Options:
– 8.0 kW 230 V ~ (7.4 kW 220 V ~)
– 6.0 kW 230 V ~ (5.5 kW 220 V ~)
(The required optional bridge can be found under accessories.)
• To guarantee compliance to relevant safety regulations, an all-pole
separator must be fitted during installation. The contact opening
must be at least 3 mm.
• Terminal
BZ45Z20M
(special accessories) can be used if the
connecting cable is fed into the continuous-flow heater via one of the
bottom holes
14a
!
• The wires must not interfere with the operation of release button A on
the safety temperature limiter.
Connection Options (Fig. A)
Definitiv wiring diagram in the appliance:
Installation note
• The installation of non plug-in ready appliances must be undertaken
by the respective utility operator or by a qualified specialist company,
who can also assist you when you are requesting the approval of
the utility company for installation of the appliance.
V. Mounting the cover onto the heater
VI. Startup
The device is compliant to IEC 61000-3-12.
• Switch on via the heater fuses in the domestic wiring.
• Turn on the hot water tap and check the water temperature.
• Explain the appliance to the user and please give him the operating
instructions.
Priority switch for combination with electric storage heaters (Fig. A)
If the heater is going to be operated in this way, a priority switch must
be connected into the line connecting the L2 phase to the appliance.
It should be mounted on the meter or distribution panel.
3
Specifications
* Plus any pressure loss at the tap mixer.
VII. Dimensions
4
Special accessories
•
BZ45U20
Pipe set: for use of the continuous-flow heater as an under
sink appliance
• Intermediate terminal block
BZ45Z20M
: Required when the mains
connecting cable is fed in through the bottom access hole
14a
.
• Priority switch (load shedding relay)
BZ45L21
:
for operation with the priority circuit
• Mounting set
BZ45K24M
: for surface-mount installation
• Truncated connecting piece sealed at rear for water connection from
below (e. g. cold water connection via fitting mounted below heater):
f1
Safety temperature limiter with mains terminals 1-3-5.
l2
Change-over terminal strip
(The required optional bridge for the 6 kW 230 V ~/5.5 kW
220 V ~ circuit can be found under accessories.)
a, b
Control line for the electricity supply company connected
to the coil input on the charging contactor.
f1
Safety temperature limiter with mains terminals.
f3
Priority switch (current relay).
TR1000 12 B
Rated power as delivered [kW] / Rated voltage
Connection Options
12 kW Y 400 V 3 ~ (11 kW Y 380 V 3 ~)
8.0 kW 230 V ~ (7.4 kW 220 V ~)
6.0 kW 230 V ~ (5.5 kW 220 V ~)
Switch-on point [I/min]
3.6
Mixed water [I/min] at rated power
approx. 38 °
6.5
approx. 50 °C
(supply temperature 12 °C)
4.4
Minimum flow pressure of appliance* [MPa (bar)]
with flow limiter
0.3 (3)
without flow limiter
0.2 (2)
Energy efficiency class
A
Load profile
XS
Annual energy consumption [kWh]
474
Daily energy consumption [kWh]
2.178
Sound power level [dB]
15
Hot water heating energy efficiency [%]
38.9
Elbow joint, “cold” (right)
Order no.
056169
Elbow joint, “hot”, (left)
Order no.
255568