Page 6 from 43
6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
3.2
Water connections
Requisite
Observations
Confirmation
Water pipes were cleaned
before connected to the
appliance?
Leakage test was done
successfully?
Inlet water filter was checked
and is cleaned, ensuring the
necessary water flow?
Accessories for water
connections are adequate?
Water pressure and flow are
according to the appliance
specifications?
- Nominal pressure: 1- 4 bar
- Minimum pressure: 0,15 bar
- Maximum pressure: 12 bar
Table 3 – Check list hydraulic connections
3.3
Gas connection
Requisite
Confirmation
The appliance is suitable for the available gas type?
Pressure reducer and gas pipe are adequate for the required
pressure and gas flow?
Accessories for gas connection are adequate and according to
the country specification/standards?
Table 4 – Check list for gas connections
3.4
Flue Exhaustion
The correspondent appliance manual have indicated the maximum flue length according model
and flue type orientation so will be required to have configured in HMI.
Flue Exhaustion
▶
Access menu AA.
▶
Scroll until find F9.
▶
Press ok
▶
Scroll and select the flue length
▶
Press ok
Length selected
Model
Flue Length
Parameter
12
0 – 4 m
00
= 4
01
15
0 – 2 m
00
2 – 4 m
01
17
0 – 2 m
00
2 – 4 m
01
Table 5 – Flue Configurations for MPP1 (5600)