Page 18 from
43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
4.9
Box Temperature sensor
The Box air temperature is measured by a 10 kΩ NTC (See table with characteristic
values) and is assembled inside the room sealed box, in order to monitor the temperature
inside of the cabinet.
Pict.24 – Box air temperature sensor
4.10
Water Flow Sensor
Water flow is measured by a turbine flow sensor that is fed by a DC signal of 5 V, and
gives a proportional feedback to the measured water flow.
-
Flow rate to operate the appliance: 2.8 l/min
-
Flow rate to shut off the appliance: 2.4 l/min
Water flow characteristic curve formula
:
f = 6.9 x Q
Note:
f is output frequency (Hz)
Q is water flow rate (L/min)
Flow (L/min)
Frequency (Hz
)
15
103.5
14
96.6
13
89.7
12
82.8
11
75.9
10
69
9
62.1
8
55.2
7
48.3
6
41.4
5
34.5
4
27.6
3
20.7
2
13.8
Table 8 – Water flow sensor values