CC404 

|

 

Operators Guide | 4.0  

Arming the System 

 

 

Bosch Security Systems | 7/05 | F01U009494B 

 

Forced Arming

 

Arming the system when a zone is not sealed is 
known as forced arming. If the system is not armed 
and a long beep sounds, forced arming is not 
permitted. If this is the case, ensure that all zones are 
sealed or manually isolated before arming the system. 

4.1 

Arming in AWAY Mode 

When you leave your premises and require all zones 
to be in a ready state to detect intrusion, arm the 
system in AWAY Mode. When returning to your 
premises, disarm your system (see 

Section 5.0 

Disarming the System) 

so you do not sound a false 

alarm. 

There are two different methods for arming the 
system in AWAY Mode. One method is standard 
and is always available. The other method is optional 
and might be disabled by your installer. 

To arm in AWAY Mode using the first method: 

Enter your user code and press [#] (for example, 
[2 5 8 0 #]).  
Two beeps sound and the AWAY indicator lights. 
Exit time starts. 

To arm in AWAY Mode using the second 
method: 

Hold down [#] until two beeps sound. 
The AWAY indicator lights and exit time starts. 

4.2 

Arming in STAY Mode 1 

STAY Mode 1 is only used when the perimeter and 
unused areas of the premises must be armed to detect 
if an intruder is entering the premises. At the same 
time, it allows you to move freely within an area that 
is automatically isolated. 

 

 

Only your security company can 
program zones automatically isolated in 
STAY Mode 1. 

 

There are two different methods for arming the 
system in STAY Mode 1. One method is standard 
and is always available. The other method is optional 
and might be disabled by your installer. 

Entry Guard Timer for STAY Mode 1 

When arming the system in STAY Mode 1, an 
optional entry timer called Entry Guard Timer for 
STAY Mode 1 is available. Use this entry timer to 
delay the sirens if a zone is not automatically isolated 
and activates an alarm. Entry Guard Timer for STAY 
Mode 1 is the delay time used for all zones except 
24-hour zones when the system is armed in STAY 
Mode 1 or STAY Mode 2. 

If the Entry Guard Timer for STAY Mode 1 is 
programmed and a zone not automatically isolated is 
activated, the codepad beeps twice per second until 
the entry timer expires or the system is disarmed. If 
the alarm condition is not reset by entering your user 
code and pressing [#] (for example, [2 5 8 0 #]) 
before the entry timer expires, the sirens sound an 
alarm. Only your installer can program this feature. 

To arm in STAY Mode 1 using the first method: 

Enter your user code and press [*] (for example, 
[2 5 8 0 *]).  
Two beeps sound and the STAY indicator lights. Exit 
time starts counting. 

Any zones programmed to be automatically isolated 
in STAY Mode 1 flash until exit time expires. At the 
end of exit time, all zones selected to be 
automatically isolated turn off and the codepad gives 
one short beep. 

To arm in STAY Mode 1 using the second 
method: 

Hold down [*] until two beeps sound. 
The STAY indicator lights and exit time starts. 

Any zones programmed to be automatically isolated 
in STAY Mode 1 flash until exit time expires. At the 
end of exit time, the zone indicators turn off and the 
codepad sounds one short beep. 

4.3 

Arming in STAY Mode 2 

STAY Mode 2 is used only when you want to arm 
the perimeter and unused areas of the premises to 
detect an intruder while you move freely within an 
automatically isolated area. Any Master Code user 
can program zones to be automatically isolated in 
STAY Mode 2. 

Entry Guard Timer for STAY Mode 2 

When arming the system in STAY Mode 2, an 
optional entry timer called Entry Guard Timer for 
STAY Mode 2 is available. Use this entry timer to 
delay the sirens if a zone is not automatically isolated, 
but activates an alarm. Entry Guard Timer for STAY 
Mode 2 is the delay time used for all zones, except 
24-hour zones, when the system is armed in STAY 
Mode 1 or STAY Mode 2. 

If the Entry Guard Timer for STAY Mode 2 is 
programmed and a zone not automatically isolated 
activates an alarm, the codepad beeps twice a second 
until the entry timer expires or you disarm the 
system. If you do not reset the alarm by entering 
your user code and pressing [#] (for example, 
[2 5 8 0 #]) before the entry timer expires, the system 
activates the sirens to sound an alarm. Only your 
installer can program this option. 

Summary of Contents for Solution 880

Page 1: ...Enter your code AWAY or Press button 1 or 2 on pendant PANIC ALARM This will create an audible alarm On code pad press STAY and AWAY simultaneously On pendant press both buttons 1 2 simultaneously TO SILENCE PANIC ALARM Enter your code AWAY or Press either button 1 or 2 on pendant Entry time is the time allowed to disarm the system after you have opened the first entry delay zone During entry time...

Page 2: ...EN Operators Guide Solution 844 CC404 ...

Page 3: ...connect this equipment should it become physically damaged and arrange for its disposal or repair The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal Before reporting such occurrences as faults please check the line with a standard telepermitted telephone and do not report a fault if the telephone per...

Page 4: ... Off 13 14 0 Reset Latching Outputs 13 15 0 Codepad ID Buzzer Tone Change 13 16 0 Testing 13 16 1 Horn Speaker Test 13 16 2 Bell Test 13 16 3 Strobe Test 13 16 4 Walk Test Mode 13 16 5 Test Report 13 17 0 Event Memory Recall 14 18 0 Day Alarm 14 19 0 Remote Arming By Telephone 14 20 0 Domestic Dialling 15 20 1 Acknowledging Domestic Calls 15 20 2 Programming Domestic Telephone Numbers 15 20 3 Disa...

Page 5: ...stem can be tailored to meet all requirements quickly and easily 2 0 Features The Solution 844 Control Panel uses the latest in microprocessor technology to provide you with more useful features and superior reliability and performance The main features of the control panel are Eight programmable User Codes STAY Mode and AWAY Mode operation Four programmable burglary zones Four programmable 24 hou...

Page 6: ...r selected to be isolated 3 2 AWAY Indicator The AWAY indicator shows the system is armed in AWAY Mode The AWAY indicator also flashes in unison with the STAY indicator when programming the control panel Refer to Section 4 1 Arming in AWAY Mode on page 7 for information on the different methods of arming the system in AWAY Mode Table 2 AWAY Indicator Status Definition On System is armed in AWAY Mo...

Page 7: ...e codepad or end of exit time occurred when armed in STAY Mode 1 or STAY Mode 2 Two short beeps The system accepted your code Three short beeps The system executed the requested function One long beep Indicates the end of exit time when armed in AWAY Mode or the requested operation was denied or aborted One beep every second Walk Test Mode is currently active or it is a warning before automatic ar...

Page 8: ...STAY Mode 2 If the Entry Guard Timer for STAY Mode 1 is programmed and a zone not automatically isolated is activated the codepad beeps twice per second until the entry timer expires or the system is disarmed If the alarm condition is not reset by entering your user code and pressing for example 2 5 8 0 before the entry timer expires the sirens sound an alarm Only your installer can program this f...

Page 9: ...der can program up to eight user codes for the system To add a user code 1 Enter your four character Master Code and press 1 for example 2 5 8 0 1 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the user code number 1 to 8 and press for example 2 for User 2 or 8 for User 8 Two beeps sound and the selected user number appears on the codepad indicators 3 Enter the digits required fo...

Page 10: ...s with confidence Table 8 Keyfob Audible and Visual Indications Indication Definition One beep System disarmed Two beeps System armed in AWAY Mode Two tone beep System armed in STAY Mode 3 sec strobe System disarmed 6 sec strobe System armed in AWAY or STAY Mode 8 0 Alarms 8 1 Duress Alarm A codepad duress alarm is used as a silent hold up alarm This only occurs when a user adds 9 to the end of a ...

Page 11: ...hes If you selected an incorrect zone to isolate enter the incorrect zone number again and press Repeat Step 2 if you are isolating more than one zone until all zones you want to isolate are selected 3 Press after you isolate all selected zones Two beeps sound and the system returns to the disarmed state 9 2 Code to Isolate Only the user codes with the Code to Isolate priority level can isolate zo...

Page 12: ... time fault registers every time the system powers down This type of fault does not cause the FAULT indicator to display on the codepad unless your installer programmed the automatic arming time Refer to Section 10 0 Setting the Date and Time to program the date and time Sensor Watch Fail A sensor watch fault registers because one or more detection devices failed to notice any movement during the ...

Page 13: ...four character Master Code and press 3 for example 2 5 8 0 3 Three beeps sound and the STAY and AWAY indicators flash 2 Press 1 to select the Telco Arm Sequence Three beeps sound 3 Enter the call forward sequence for example 6 1 Phone Number to program the Call Forward No Answer sequence or 2 1 Phone Number to program the Call Forward Immediate sequence To program a in the Telco Arm Sequence enter...

Page 14: ...tiple codepads are installed each codepad can sound a different tone 16 0 Testing There are five functions for testing that your system operates correctly 16 1 Horn Speaker Test Press and hold 1 until two beeps sound The horn speaker sounds for 2 sec 16 2 Bell Test Press and hold 2 until two beeps sound The bell output turns on for 2 sec 16 3 Strobe Test 1 Press and hold 3 until three beeps sound ...

Page 15: ...alarm turns on If a zone programmed for day alarm operation is activated when the system is disarmed the codepad beeps To turn day alarm off Hold down 4 until two beeps sound Day alarm turns off 19 0 Remote Arming By Telephone Use this feature to arm your system by telephone from any remote location For security reasons you cannot disarm the system using this method This feature requires a touch t...

Page 16: ...d Number to Program Digit Required Number to Program 0 0 8 8 1 1 9 9 2 2 3 3 1 4 4 2 5 5 4 sec pause 3 6 6 break 4 7 7 20 2 Programming Domestic Telephone Numbers If your system is configured for domestic dialling the Master Code holder can program the telephone numbers the control panel calls if an alarm occurs To program telephone numbers 1 Enter your four character Master Code and press 2 for e...

Page 17: ... sealed 1 Alarm The corresponding zone is unsealed and in alarm 2 Bypassed A system operator manually isolated the corresponding zone Refer to Section 9 0 Isolating Zones for information about manually isolating a zone s before arming the system 3 Trouble A zone was unsealed when exit time expired System Status The system status information is divided into the four digits identified in Table 13 Ta...

Page 18: ... Pager Display 678 01200000 9000 1 2 3 4 5 6 8 7 1 2 3 4 5 6 7 8 1 Subscriber ID number 2 Zone status 3 System status 4 0 Zone Normal 1 Alarm 2 Zone Bypassed 3 Zone Trouble 5 8 Disarmed 9 Armed 6 0 Normal 1 Panic Duress 2 Fire Alarm 3 Medical Alarm 7 0 AC Normal 1 AC Failure 8 0 System Normal 1 System Fault ...

Page 19: ...ber ID Alarm Zone 02 Restore Zone 2 Subscriber ID Restore Zone 02 Alarm Zone 3 Subscriber ID Alarm Zone 03 Restore Zone 3 Subscriber ID Restore Zone 03 Alarm Zone 4 Subscriber ID Alarm Zone 04 Restore Zone 4 Subscriber ID Restore Zone 04 Alarm Zone 5 Subscriber ID Alarm Zone 05 Restore Zone 5 Subscriber ID Restore Zone 05 Alarm Zone 6 Subscriber ID Alarm Zone 06 Restore Zone 6 Subscriber ID Restor...

Page 20: ...namic Battery Testing Monitors and tests the condition of your backup battery Entry Time or Entry Delay The time allowed by a zone to disarm the system after you enter your premises External Equipment Any devices connected to your system such as detectors codepads and sirens Forced Arming Enables you to arm your system even though one or more zones are unsealed Handover Delay The system is armed a...

Page 21: ...em automatically isolates zones when you arm the system in STAY Mode 2 Only the Master Code holder can program zones to be isolated automatically in this mode Telco Arm Sequence Telco arming automatically diverts your telephone number to another telephone when the system is armed in AWAY Mode In Australia this feature is called Call Forward Telco Disarm Sequence Telco disarming automatically calls...

Page 22: ...24 0 Installation Notes Bosch Security Systems 7 05 F01U009494B 21 24 0 Installation Notes Company Name Technician s Name Technician s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes ...

Page 23: ... STAY Mode 1 or are programmed for day alarm operation Isolated In STAY Mode 1 Day Alarm Enabled Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 User Code Names Master Code Default 2580 User Code 1 Y User Code 9 User Code 2 User Code 10 User Code 3 User Code 11 User Code 4 User Code 12 User Code 5 User Code 13 User Code 6 User Code 14 User Code 7 User Code 15 User Code 8 User Code 16 ...

Page 24: ...WAY Mode YES NO Automatic Arming Time AM PM Automatic Arming STAY Mode YES NO Automatic Disarming Time AM PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Isolating Method Standard Isolating YES NO Code To Isolate YES NO Communication Options Back To Base Reporting YES NO Domestic Reporting YES NO Domestic Reporting Number Of Beeps Other System Information Siren Run Time Minutes Sensor W...

Page 25: ...h 12 VDC Rechargeable sealed lead acid battery Dimensions case packed in carton 30 6 cm x 26 2 cm x 8 4 cm 12 1 in x 10 3 in x 3 3 in Weight 2 5 kg 5 5 lb Supplier Code N771 New Zealand Telepermit PTC 211 98 085 Malaysia Approval Number Pending The Austel permit issued for this product is subject to the following conditions The Solution 844 Model CC404 Control Panel can only be powered by a Bosch ...

Page 26: ...ors 5 Communciation Fail 11 D Date and Time 11 Day Alarm 14 Deleting Radio User Codes 8 Deleting User Codes 8 Detectors 18 Disarmed 18 Disarming 8 Domestic Dialling 15 Acknowledging Domestic Calls 15 Disable 15 Programming Domestic Telephone Numbers 15 Duress Alarm 9 E E2 Fault 11 Entry Delay Entry Time 18 Entry Guard Timer 7 Event Memory Recall 14 External Equipment 18 F Fault Analysis 11 Fault D...

Page 27: ...STAY Indicator 5 STAY Mode 1 7 19 Entry Guard Timer 7 STAY Mode 2 7 19 Entry Guard Timer 7 Programming Zones 8 Strobe Test 13 System Disarmed 5 T Tamper Alarm 10 Telco Arm Sequence 12 19 Telco Disarm Sequence 19 Telephone Line Fail 11 Test Report 13 Testing Bell Test 13 Horn Speaker Test 13 Strobe Test 13 Test Report 13 Walk Test 13 U Unsealed 19 User Codes 19 Adding 8 Adding Radio Users 8 Deletin...

Page 28: ...CC404 Operators Guide Notes EN 27 Bosch Security Systems 7 05 F01U009494B 27 Notes ...

Page 29: ... 2005 Bosch Security Systems F01U009494B SKU 920054 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 ...

Reviews: