Solution 16
plus
22
Bosch Security Systems 09/06 BLCC100R
Quick Start Guide
Test RF Device
MENU 3-3-2
Inputs > Global Input Options >
EOL Value
MENU 3-4-0
0 = No EOL
5
1 = 1K0
6 = 4K7
11 = 6K8 Alarm with 2K2 Tamper
2 = 1K5
7 = 5K6
12 = 10K Alarm with 10K Tamper
3 = 2K2
8 = 6K8
13 = 22K
4 = 2K7
9 = 8K1
14 = 3K3 with 6K8 Tamper
5 = 3K3
10 = 10K
15 = Split EOL (Parallel)
(3K3 = Primary 6K8 = Secondary)
Use Keys [
] and [
] keys or enter 0 - 15 Then Press [OK] To Program
Globally The EOL Resistor For All Zones.
(*** System Wide Parameter ***)
Inputs > Global Input Options >
Keyswitch Options
MENU 3-4-1
0
= Latching - All On/Off
5 =
Momentary All On/Off
0
1 =
Latching - All On
6 =
Momentary - All On
2 =
Latching Part On/Off
7 =
Momentary - Part
On/Off
3 =
Latching - Part On
8 =
Momentary - Part On
4 =
Latching Off
9 =
Momentary - Off
Use Keys [
] and [
] keys or enter 0 - 9 Then Press [OK] To Program
How The Keyswitch Will Operate.
(*** System Wide Parameter ***)
Zone Default Table
The table below list the default values for all zone parameters in the Solution 16
plus
. By default, zones 5 to 16 are set as
Instant zones. Zones marked as Not Used do not require EOL resistors to be fitted.
Programming Option
Zone 1
Zone 2
Zone 3
Zone 4
Zones 5 to 16
Zone Name
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5 - Zone 16
Zone Type
1 = Delay 1
5 = Handover
5 = Handover
5 = Handover
3 = Instant
Area Assignment
1
1
1
1
1
Pulse Count
0
0
0
0
0
Pulse Count Time (Sec’s)
120
120
120
120
120
Access Group
0
0
0
0
0
Report Route
2
2
2
2
2
Reporting Options
Lockout Dialler
Y
Y
Y
Y
Y
Report Alarm
Y
Y
Y
Y
Y
Report Alarm Restore
Y
Y
Y
Y
Y
Report Trouble
Y
Y
Y
Y
Y
Report Trouble Restore
Y
Y
Y
Y
Y
Report Bypass
Y
Y
Y
Y
Y
Report Bypass Restore
Y
Y
Y
Y
Y
Delay Report
N
N
N
N
N
Zone Options
Lockout Siren
Y
Y
Y
Y
Y
Silent Alarm
N
N
N
N
N
Inverted Seal
N
N
N
N
N
Bypass Allowed
Y
Y
Y
Y
Y
Sensor Watch
N
N
N
N
N
Armed When Part On
Y
Y
Y
Y
Y
Reserved
N
N
N
N
N
Test On Exit
N
Y
Y
Y
Y
Table 15: Zone Defaults
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1
Tamper On Short
N
2
Reserved
N
3
Response Time 500ms
N
4
Reserved
N
5
Keyswitch Open / Close Report
Y
6
Reserved
N
7
Reserved
N
8
Reserved
N
Use Keys [
] and [
] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [
] will display
to indicate option set. Press [OK] To Save when finished.
(*** System Wide Parameter ***)
Inputs > PGM Input >
Input Type
MENU 3-5-0
0 =
Disabled
0
1 =
Latching - On/Off (RF Relay)
2 =
Momentary - On/Off (RF Relay)
3 =
Digiflex RF On/Off
6 =
Ness Serial RF Receiver
4 =
Bosch Serial RF Receiver
7 =
Inovonics Serial Receiver
5 =
C Type Serial RF Receiver
8 =
Secure Wireless Receiver
Enter 0 - 7 + [OK] to select the interface method used for the given
RF receiver. The latching and Momentary options will control all areas
on the system. For individual area control via RF relay you should use a
keyswitch zone(s) in the area you want to control.