Features
Listed below are the main features of the Solution 16
plus
Control Panel.
Individual Box Tamper Circuit Monitoring
Report Via Email (Internet)
Telephone Line Busy Tone Detect
RAS Intelli-connect® CLI Caller Line Identification
Daylight Savings
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary Pin Code
Dual Reporting
Dual Redundant Reporting
Alarm Report Abort/cancel Options
8 Programmable Holiday Calendars
8 Programmable Schedules
16 fully programmable Zones
Fire Alarm Verification
48 Pin Codes
3 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 13)
Supervised Siren Driver
Partitionable To 8 Areas
Dialler Reports SIA, Contact ID, SMS and Email Formats
Supervised LAN Keypads (Maximum 8 Keypads)
Keyswitch Input
256 History Event Memory
EMI / Lightning Transient Protection
Fully Menu Text Programmable
Programmable Via Solution Link Software
(Remote/Direct)
Telephone Line Fail Monitor
Time Executed Functions
60 Output Event Types
Exit Restart
Expansion Module Supervision
DTMF Tone Decoder Built In
Remote Arming
Over view
Zones
The Solution 16
plus
control panel provides up to 16 separate
zones of protection. Zone programming determines the
panel’s response to open/short and tamper conditions on
the zone loop.
Areas
The control panel supports up to 4 separate areas. You can
assign all zones to a single area, or you can assign each
zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports to the
receiving party (ie. Security company monitoring station,
mobile phone etc).
Keypads
You can connect a maximum of 8 fully supervised keypads
to the control panel. The available current affects the total
number of keypads that you can connect without the need
to provide additional power supplies.
History Log
The control panel can store up to 256 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel’s history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the SolutionLink upload/
download software.
Programming
You can program the Solution 16
plus
either by a keypad or
using a personal computer using the Solution Link upload/
download software.