Error code / error indication / signal
Malfunction
E:20-60 lights up alternately.
Cause
Troubleshooting
The appliance has
detected a calcified
heating element.
1.
Descale the appliance.
2.
Use the appliance with the
water softener.
1
E:30-00 lights up alternately.
Aquastop system is
activated.
1.
Close the tap.
2.
Contact the "service
Page 59.
E:31-00 lights up alternately.
Aquastop system is
activated.
1.
Close the tap.
2.
Contact the "service
Page 59.
E:32-00 lights up alternately
or water supply indicator
lights up.
Water supply hose is
kinked.
▶
Route the water inlet hose
without kinks.
Tap is closed.
Tap is clogged or calcified.
▶
Turn on the tap.
▶
Turn on the tap.
The amount of water flowing
in when the tap is open is at
least 10 l/min.
The strainers in the water
connection of the supply or
AquaStop hose are
clogged.
1.
Turn off the device.
2.
Remove the plug from the socket.
3.
Turn off the tap.
4.
Unscrew the water connection.