64
Interface description
6
en
Functional description
Setting the maximum time for the locking procedure. If the maximum
time for a locking procedure is exceeded, the motor stops the process
and the unit goes into an error status.
Send
SET;MOT_LOCK_TIMEOUT;500
Description of
transmission
parameters
Maximum time for the locking procedure
Transmission type
UINT32(ms)
Value range
Min = 200, max = 2000, default = 500
Receive
SET;MOT_LOCK_TIMEOUT;OK
Description of response
value
Status
Response type
ENUM(OK,ERROR)
Persistence
Persistent
6.5.2
Sensors
Functional description
Switching on/off compensation
Send
SET;ENABLE_COMPENSATION;TRUE
Description of
transmission
parameters
Compensation status
Transmission type
ENUM(TRUE, FALSE)
Receive
SET;ENABLE_COMPENSATION;OK
Description of response
value
Status
Response type
ENUM(OK,ERROR)
Persistence
Persistent