Feedback to weld timer
Different type-specific options are available to signal gun closed or pro
grammed force reached to the timer.
The required option can normally be selected through the ”Operating
mode” parameter in the ”Programming / Electrode” BOS window.
The existence of the „Operating mode“ parameter is also type-speci
fic.
Shield
Timer
X2
1
2
3
4
5
GND for terminals 1 and 3
D
X9
1
2
3
4
5
6
analog force input (1 V = 1 kN)
GND
Shield
D
analog pressure input (0...10V)
digital pressure input (+24 V
DC
)
Fig.42:
Possibly available feedback signal inputs for pressure/force
Information on the inputs available in your unit and how the WT re
acts to these signals is provided in the type-specific manual.