Electric Drives
and Controls
3
−
9
Bosch Rexroth AG
BT 6.00
1070080078 / 03
Assembly and Connection
Power supply:
via pin 15 (+24V) and pin 11 (0V).
Safety extra-low voltage (SELV) in accor-
dance with DIN EN 61131.
19.2 ... 30.2 V
DC;
typ. 24 V
DC
Residual ripple max. 10 %.
.
The BT 6.00 HPG can be supplied from, e.g., the X5 power output of
the weld timer.
Power input:
< 0.3 A
Peak current:
0.5 A
Protection against polarity
reversal:
Protective diode
Fusing:
through semiconductor fuse, self-regen-
erating.
For more information, refer to page 5
−
3.
Communication interface (via pins 2, 3 and 5):
Type:
RS232C, electrically isolated
Transmission rate:
19200 bit/s
Parameter:
(8 data bits, even parity, 1 stop bit)
Transmission:
PS5000 block protocol with CRC16
1
2
3
RX
TX
4
5
GND
6
7
8
9
PS 5000 / PS 6000
(X1; submin. D, 9-pin
)
Plug
1
2
3
4
5
6
7
8
9
Control station
Socket, 15-pin
10
11
12
13
14
15
H01
H02
PS 5000 / PS 6000
(X5)
24V
0V
BT 6.00 HPG
Connection of BT 6.00 HPG (manual programming terminal) to control
station
.
The BT 6.00 HPG can be directly connected to the weld timer using
a proper adapter.
Part no. adapter: 1070 088 302.