3
−
2
Electric Drives
and Controls
Bosch Rexroth AG
BT 6.00
1070080078 / 03
Assembly and Connection
Front panel dimensions
120
168
Required
assembly cutout
112
+1,
−
0
160
+1,
−
0
All dimensions in mm.
Required installation depth: approx. 40 mm.
Maximum thickness of mounting wall: 14 mm
Front panel thickness: 4 mm
Dimensions / Assembly cutout for built-in unit
L
Please refer to the information in chapter ”Safety Instructions” relative to
installation and assembly.
L
Install the BT 6.00 so that ergonomic operation is guaranteed. The opti-
mum reading angle of the LCD display is approx. 90
_
.
Remember how quickly the front panel can become dirty with a station-
ary inclined or horizontal installation.
max. 90 degrees
BT6 6.00
Optimum viewing angle:
90 degrees
L
From the place the terminal is installed, the operator’s view of any mov-
ing machine elements must never be obstructed, and he must be able to
immediately operate the system’s EMERGENCY-STOP device in the
event of danger!
L
Avoid installation places which are exposed to direct sunshine (reduc-
tion of display legibility; additional heat).
L
Provide a minimum upper and lower clearance of at least 30 mm for ven-
tilation and cable routing.
L
Keep as far as possible away from sources of interference, however at
least 25cm.