3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 225
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
9.8.4.4
IPM
Settings
Data
IPM
Use this menu item to define the setting for communication with Rexroth IPM Protocol of the Nexo
cordless Wi-Fi nutrunner.
Table 9–72:
IPM tab
Element
Description
Active
If this check box is activated, communication with the Rexroth IPM Protocol
is activated.
IPM IP address
IP address of the IPM gateway to which the data are to be sent (target
address).
IPM port
IP port of the IPM gateway to which the data are to be sent (target address).
Value range: 0 - 65535
Default setting: 5501
ID code mask
The IPM data set has different (text) data fields to which flexible parts of the
ID code can be mapped. The maximum number of characters that can be
entered is 255.
This element can be used for this purpose, with the following characters
being allowed for the ID code mask (IDCodeMask):
– _
Placeholder; character at this position is ignored
– *
New placeholder character to provide a clearer view
– I
Character at the position marked by I is taken over in IPM ID code
IP code data
The IPM data set has different (text) data fields to which flexible parts of the
ID code can be mapped. The maximum number of characters that can be
entered is 255.
This element can be used for this purpose, with the following characters
being allowed for ID code data (IDCodeKeys):
– A
AFO extension field
– V
Fields for process number
– B
Fields for component carrier ID
– T
Fields for component type designation/type number
– Z
Additional ID
IPM version
Version of the IPM protocol that is used for transmission.
The version must comply with the version supported by the IPM gateway
used.
AFO
Work sequences (definitions of the individual entries per work sequence, see
table
– Add
Inserts a new AFO
– Add Loosen
Adds a new AFO, based on the selected channel for program 99
("Loosen")
– Remove
Deletes an AFO
Save
Click
Save
to save the edited data.
Discard
Click
Discard
to discard the edited data.
Restore defaults
All settings in this tab are reset to the factory setting.