226
Bosch Rexroth AG
| Tightening Technology
3 608 870 A47
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-
Each work sequence (AFO) is represented by one line in the AFO table, see table
. In the AFO table,
an unlimited number of AFOs can be inserted and deleted.
Table
is a schematic presentation of the clear assignment of the combination of channel number
and program number ("physical process information") to a work sequence ("logic IPM feature").
Table 9–73:
Assignment of the combination of channel number and program number
Element
Description
Active
– Ticked
Data is forwarded to the IPM gateway.
– not checked
Data with this channel/program number is not forwarded to the IPM
gateway.
Applications:
– AFO is defined, however not activated:
This option is used if the transmission of the results is to be avoided, e.g.
loosen processes.
– Tightening program not defined in the AFO list is tightened:
An AFO (AFO name) is automatically generated and the tightening result
is sent to the IPM gateway, see table footnote
1
.
Channel no.
The channel number can be edited in the
Settings
-
Configuration
menu.
Prg
Selects the program number for this work sequence.
AFO
Name of the work sequence (no more than 30 characters)
Allowed character set: 7-bit US-ASCII (no umlauts)
Description
Allowed character set: 7-bit US-ASCII (no umlauts, no more than 30
characters)
This field may remain empty so that the description can later be assigned to
this AFO at the server. In this case, you can then e.g. create country-specific
descriptions with umlauts.
Graph filter
Selection of the results type to be stored:
– OK/NOK graphs
All result graphs
– OK graphs
Limited to graphs with OK result
– NOK graphs
Limited to graphs with NOK result
– No graphs
No results graphs
OK graph
Defines how the graph is to be transmitted to the IPM system in case of OK:
– Last step
Graph range of the last tightening step
– All steps
Entire tightening graph
NOK graph
Defines how the graph is to be transmitted to the IPM system in case of NOK:
– Last step
Graph range of the last tightening step
– All steps
Entire tightening graph
Tension relief
– Ticked
Tension relief range is not cut off
– not checked
Tension relief range is cut off
Absolute angle
If this option is selected, the graph is converted into a presentation where it
rises monotonically with the angle.
Loosen
If this option is selected, the tightening job is interpreted as "loosen".