5
Transport and storage
5.1
Transport (shipping) instructions
The motors have to be transported in their original packaging, complying with
2K2, 2B1, 2C2, 2S2, 2M1 acc. to DIN EN 60721-3-2.
Please observe the following classification limitations:
●
Transport temperature range -20 ... +80 °C
●
Relative air humidity max. 75% (at +30 °C)
●
No occurrence of salt mist
Before transport, discharge the liquid coolant from liquid-cooled
motors to avoid frost damage.
5.2
Instructions on machine transport
Never touch the connection points of electro‐
static sensitive devices!
NOTICE
Installed components (e.g., KTY84, encoder) may contain
electrostatic sensitive devices (ESD).
Observe the ESD safety measures.
Risk of injury and material damage due to im‐
proper handling during transport!
WARNING
Only use hoisting gear suited for the weight of the motors.
Use lifting sling belts or lifting eye bolts. Secure the lifting eye
bolts before use.
Never walk under hanging loads.
Do not lift the motor at the shaft or on the optional fan hous‐
ing.
Use suitable protective equipment and protective clothing
during transport, and wear safety shoes.
①
①
Eye bolts (check firm seating before use)
Fig. 5-1:
Lifting and transporting motors
Before transporting the motor, determine the weight of the motor. For more
details about motor weight, please refer to the type plate or the project plan‐
ning manual (Technical data).
MSK Synchronous Servomotors
15/57
Transport and storage
R911325169_Edition 03 Bosch Rexroth AG
Summary of Contents for rexroth MSK 030
Page 1: ...MSK Synchronous Servomotors Operating Instructions R911325169 Edition 03 ...
Page 20: ...6 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Page 22: ...8 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Page 32: ...18 57 MSK Synchronous Servomotors Bosch Rexroth AG R911325169_Edition 03 ...
Page 69: ...Notes MSK Synchronous Servomotors 55 57 ...
Page 70: ...Notes 56 57 MSK Synchronous Servomotors ...