Symbols used to describe the connection points
Screw terminal
block
Spring terminal
Thread
Max. connection
cross section
Stripped length
Max. tightening torque
Tab. 4-5:
Symbols
Connection point
mm
2
(AWG)
mm
Nm
XD1, XD1.2
6 (10)
10
0.8
XD10
6 (10)
10
0.8
XG3
1.5 (16)
10
-
XG14
6 (10)
10
0.8
XG34
1.5 (16)
10
-
M5; 4 (12)
-
3.1
Tab. 4-6:
Connection points
For proper function of the motor thermal management connect the motor
thermal sensor as described in the wiring diagram. Otherwise motor overtem‐
perature sensing is not provided by the drive.
For Rexroth motors with data memory in the motor encoder, such as MSK,
the motor overload protection level is set automatically while connecting the
motor to the drive. There is no adjustment necessary. Otherwise refer to the
Rexroth firmware documentation.
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
21/29
Instructions for use
R911374765_Edition 01 Bosch Rexroth AG