4.6
KMV03, replacing the fuse
Lethal electric shock by live parts with more
than 50 V!
WARNING
Before working on live parts: De-energize installation and secure power
switch against unintentional or unauthorized re-energization.
Wait at least 30 minutes after switching off the supply voltages to allow dis‐
charging.
Check whether voltage has fallen below 50 V before touching live parts!
Replacing the fuse
1. Switch off power voltage to drive system.
2. Wait at least 30 minutes to allow discharging.
3. Dismount cover.
4. Open fuse carrier.
5. Remove fuse.
6. Insert new fuse (material number: R911319963) FWP-30A14Fa by
BUSSMANN.
7. Mount cover (screws: M4, 2.5 Nm).
Cover of fuse
Replacing the fuse
Tab. 4-7:
Fuse
24/29
Instructions for use
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter