6.8
X32 (single-axis), analog input
View
Connec‐
tion
Signal name
Function
1
GND_100
Connection for inner cable shield
2
IA_1-
Analog input
3
IA_1+
Spring terminal (con‐
nector)
Unit
min.
max.
Connection cable
Stranded wire
mm
2
0.2
1.5
AWG
24
16
Stripped length
mm
-
10
Shielding
-
-
Only use shielded cables for cable lengths > 30 m.
Tab. 6-10:
Function, pin assignment, properties
Shield connection
chapter 9.3 "Analog inputs/outputs: Shield connection" on page 130
Technical data
chapter 8.8 "Analog Voltage Input" on page 123
DOK-INDRV*-CXX02******-PR03-EN-P
Bosch Rexroth AG
55/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
On-board connection points
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com