9
Technical data - other
9.1
Power consumption
9.1.1
General information
The power consumption of the control sections consists of the following com‐
ponents:
●
Basic equipment
●
Optional equipment
The control sections are supplied via the terminal connectors 24V
and 0V at the power section (24 V supply).
9.1.2
Basic circuit boards of control section
According to the options with which the configurable control sec‐
tions have been equipped, the power consumption of the optional
modules has to be added. This does not change the data for in‐
rush current and pulse width.
The power consumption is specified as the maximum value of the
respective component and can occur at individual components. In
drive systems with several components, the occurring power con‐
sumption under statistical assumptions will be lower than the cal‐
culated one.
Control
section
Power consumption P
N3
at
U
N3
= DC 24 V
[W]
max. inrush current
I
EIN3
[A]
max. pulse width
EIN3Lade
[ms]
CSB02.1A
17
1)
< 5
1
CSB02.xB
17
1)
CDB02.1B
23
2) 3)
CSH02.1B
17
2) 3)
1)
Incl. "EC" encoder interface, corresponding communication and
control panel
2)
Incl. control panel and "PFM" memory card
3)
At maximum allowed output load, plus power consumption of
optional modules
Tab. 9-1:
Power consumption of control sections
The isolated inputs/outputs at X31, X35 and X36 are not supplied
via the connections of the 24 V supply of the power section. A
separate power supply is required for these inputs/outputs.