4
Technical Data
4.1
Front Panel
VPP 21.2 BQ
VPP 21.2 BP
Display
14" TFT, 1024 × 768 pixels
Operation
Keys
Touch screen
Interface
Bosch Rexroth Design
Degree of pro‐
tection
Front panel IP 64 according to DIN 40 050, IEC 529
Fig.4-1:
Technical data of the front panel
4.2
Technical Data of the Total Device
Degree of protection
IP 40 (for closed doors)
Weight
11 kg (key device VPP 21.2 BQ)
9.15 kg (touch device VPP 21.2 BP)
Nominal input voltage
24 VDC
Input voltage range
24 VDC +20%, -15%
Noise and surge immunity
U
max
= 35 V (for t < 100 ms)
24 volts power supply unit:
Maximum power consumption
48 W
1)
Input current
2.0 A for nominal voltage 24 V
1)
Output voltages
+ 5 V ...
+ 12 V ...
Current
(max.)
6 A
0.7 A
Tolerance (incl. residual ripple)
+/- 5 %
+/- 5 %
Max. output power
38.4 W
Efficiency
0,8
Fig.4-2:
Technical data of the total device
4.3
PC
Processor
Celeron M with 1.3 GHz and integrated graphic control‐
ler with a maximum of 8 MB video memory
Random access memory
(RAM)
1 GB SO-DIMM DRAM
1)
The power supply unit requires a maximum of 48 W (24 V, 2 A) from the 24 VDC
supply. Additionally, a maximum of 24 W (24 V, 2 x 0,5 A) is required for the two
24 V outputs that are also supplied from the 24 VDC supply.
Project Planning Manual | Rexroth IndraControl VPP 21.2
Electric Drives
and Controls
| Bosch Rexroth AG
17/65
Technical Data