background image

   

DS-K1T8003 Series Fingerprint Access Control Terminal

    Quick Start Guide

UD12126B-C

1

2

3

Activation

Appearance

Installation

The default values of the terminal are as follows:

• The default IP address: 192.0.0.64

• The default port No.: 8000

• The default user name: admin

STRONG PASSWORD RECOMMENDED– 

We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, 

numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high 

security system, resetting the password monthly or weekly can better protect your product.

Activating via Device

Power on and wire the network cable after installation.

You should activate the device before the first login. 

After  powering on, the interface will be displayed as follows. 

You can create the device password and confirm the password to activate.

Exiting Key

Direction Keys

Numeric Keys/

Letter Keys

OK Key

Editing Key

Deleting 

Key

ESC

O

K

1

2

ABC

3

DEF

4

GHI

6

MNO

7

PQRS

8

TUV

9

WXYZ

5

J

K

L

OK Key: 

Press to confirm operations. Hold the key for 3 s to enter the login interface.

Deleting Key: 

Press the key to delete the entered letter or number

.

Numeric Keys/Letter Keys: 

Enter numbers or letters.

Key 0 can also represent a space key except you are using the number input method.

Exiting Key: 

Press the key to exit the menu.

Direction Keys: 

Press       ,       ,       and   

  

to move the cursor.

Editing Key: 

Press the key to enter the number 0. Hold the key to shift among 

numbers/lowercases, numbers/uppercases and symbols. 

Keypad Descriptions

©2019 Hangzhou Hikvision Digital Technology Co., Ltd. 

It includes instructions on how to use the Product. The software embodied in the 

Product is governed by the user license agreement covering that Product.

About this Manual

This Manual is subject to domestic and international copyright protection. Hangzhou 

Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. 

This manual cannot be reproduced, changed, translated, or distributed, partially or 

wholly, by any means, without the prior written permission of Hikvision. 

Trademarks

                       and other Hikvision marks are the property of Hikvision and are 

registered trademarks or the subject of applications for the same by Hikvision and/or 

its affiliates. Other trademarks mentioned in this manual are the properties of their 

respective owners. No right of license is given to use such trademarks without express 

permission.

Legal Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT 

DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”, 

WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR 

IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY 

QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD 

PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR 

AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR 

INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS 

PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN 

CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN 

ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL 

BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES 

FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING 

FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET 

SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF 

REQUIRED. 

SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN 

YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR 

USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT 

THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. 

IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, 

THE LATER PREVAILS.

Data Protection

During the use of device, personal data will be collected, stored and processed. To 

protect data, the development of Hikvision devices incorporates privacy by design 

principles. For example, for device with facial recognition features, biometrics data is 

stored in your device with encryption method; for fingerprint device, only fingerprint 

template will be saved, which is impossible to reconstruct a fingerprint image. 

As data controller, you are advised to collect, store, process and transfer data in 

accordance with the applicable data protection laws and regulations, including 

without limitation, conducting security controls to safeguard personal data, such as, 

implementing reasonable administrative and physical security controls, conduct 

periodic reviews and assessments of the effectiveness of your security controls.

Activating via SADP

1. Download SADP Software

Get the SADP software from the supplied disk or the official website. Install and run the software.

2. Activate Device: Check the inactive device from the device list. Create a password in the right side of the interface and confirm the password.

3. Edit Device IP Address: Check the device and manually edit the device IP address, Port No., Subnet Mask, Gateway, etc. 

Activating via Client Software

1. Get the client software from the supplied disk or the official website. Install and run the client software. 

2. Enter the Device Management page.

3. Click Device tab on the top of the right panel. 

4. Click Online Device to show the online device area at the bottom of the page.

     The searched online devices are displayed in the list.

5. Check the device status (shown on Security Level column) and select an inactive device.

6. Click Activate to open the Activation dialog.

7. Create a password in the password field, and confirm the password.

8. Click OK to activate the device.

9. Select an activated device in Online Device area, click     on the Operation column to open the Modify Network Parameter window. Change the 

device IP address to the same subnet with your computer if you need to add the device to the client.

Display Screen

Keypad

Fingerprint Recognition Area

Card Swiping Area

Power Interface

USB Interface

Network Interface

Wiring Terminal

14

0 mm

30 mm

155 mm

Steps:

1. Install the gang box on the wall.

    Note: 

Make sure the gang box screw holes match the mounting plate’s. The gang box here 

    is for reference only. Select an appropriate gang box to install. The gang box is not supplied. 

    The recommanded gang box dimension is 78 × 78 mm or 100 × 62 mm

.

 

2. Fix the mounting plate on the gang box with two supplied screws (SC-PM4X10-IMP).

3. Route the device cable through the cable hole of the mounting plate and  insert the cables   

     in the gang box.

4. Align the terminal with the mounting plate, and secure the terminal on the mounting plate 

    with two supplied socket hexagon screws (SC-KM3X10_3-SUS).

1

2

3

Steps:

1. Stick a mounting template on the wall at a required height, and drill 4 holes according to the mounting 

     template on the wall.

     

Note: 

The suggested distance between the device lower edge and the ground is 1.3 m.

2. Insert 4 supplied expansion sleeves of the setscrews (4_KA4×22-SUS) in the drilled holes.

3. Fix and fasten the expansion bolts in the expansion sleeves respectively.

     

Note: 

Reserve 5.2 mm to 5.5 mm of expansion bolts outside the wall for hanging the device.

4. Align four holes of the device rear panel with the fixed screws and hang the device on the wall.

     Note:

 

The additional force shall be equal to three times the weight of the equipment but not less than 

     50 N.  The equipment and its associated mounting means shall remain secure during the test. After the 

     test, the equipment, including any associated mounting plate, shall not be damaged.

With Gang Box

Without Gang Box

4

Device

Mounting 

Plate

Gang Box

Doorbell 

Button

Doorbell Button: 

Press the doorbell button and the doorbell rings.

120 mm

13

0.

6 mm

25

.1

5 mm

66.6 mm

53

.2 mm

36.5 mm

83

.6

5 mm

68.1 mm

ESC

O

K

1

2

ABC

3

DEF

4

GHI

6

MNO

7

PQRS

8

TUV

9

WXYZ

5

J

K

L

0

M4 Expansion Bolt

Expansion Sleeve

[Number]

OK Next

Input Method

Device Activation

Activation Password 

 (

8 to 16 Characters)

Notes: 

1. The pictures here are for reference only. Some models do not support card swiping 

function. For details, refer to the actual products.

2. If you enable the attendance status function, the OK key, the direction key, and the 

exiting key can be the shortcut key of the attendance status.  

0

Reviews: