28/56 Assembly
Bosch Rexroth AG, MIT: EL 2, 3 842 558 372/2021-10
7.5.2
Making the electrical connection to the product
WARNING
High electrical voltage!
Risk of serious injury or death from electric shock.
Disconnect the relevant system component before performing maintenance
or repair work.
Secure the system against being unintentionally switched on again.
• Select the control and sensor elements according to EN ISO 13849. Factor in
the load to be transported and the transport speed.
• Electrical work may only be carried out by qualifi ed personnel!
(e.g. connecting the motor)
• Observe the DIN EN 60204 standard (previously: VDE regulation VDE 0100)
for Germany, or corresponding regulations in the country of use.
Motor connection
• See assembly instructions “IndraDyn S Synchronous Motors MSM”, R 911 329 337.
SpeedCon quick locking system
Fig. 16:
558 371-35
SpeedCon quick locking system
1.
Plug the cable
connectors together in
the open position.
2.
Hand-tighten the cable
connector by turning
it 90°.