Magnetic and Electromagnetic Fields
WARNING
Health hazard for persons with heart pacemakers, metal implants and hearing aids in
proximity to electrical equipment!
•
Persons with heart pacemakers and metal implants are not permitted to enter following
areas:
–
Areas in which electrical equipment and parts are mounted, being operated or
commissioned.
–
Areas in which parts of motors with permanent magnets are being stored, repaired or
mounted.
•
If it is necessary for somebody with a pacemaker to enter such an area, a doctor must
be consulted prior to doing so. The interference immunity of present or future implanted
heart pacemakers differs greatly, so that no general rules can be given.
•
Those with metal implants or metal pieces, as well as with hearing aids must consult a
doctor before they enter the areas described above.
Otherwise health hazards may occur.
Hot Parts
CAUTION
Hot surfaces at motor housings, on drive controllers or chokes! Danger of burns!
•
Do not touch surfaces of device housings and chokes in the proximity of heat sources!
Danger of burns!
•
Do not touch housing surfaces of motors! Danger of burns!
•
According to operating conditions, temperatures can be higher than
60 °C (140 °F)
during or after operation.
•
Before accessing motors after having switched them off, let them cool down for a
sufficiently long time. Cooling down can require
up to 140 minutes
! Roughly estimated,
the time required for cooling down is five times the thermal time constant specified in the
Technical Data.
•
Wear safety gloves or do not work at hot surfaces.
•
For certain applications, the manufacturer of the end product, machine or installation,
according to the respective safety regulations, has to take measures to avoid injuries
caused by burns in the end application. These measures can be, for example: warnings,
guards (shielding or barrier), technical documentation.
1.2 Appropriate
Use
This product may only be used for the applications mentioned in the
reference documentations (see chapter “Reference Documentations”)
and under the described application, ambient and operating conditions.