70/84 Troubleshooting
Bosch Rexroth AG
, CytroPac, RE 51055-B/06.17
15.1.1 Overview of the impact of defects
Table 11: Impact of defects
Error
Possible cause
Remedy
Excessive noise level
Insufficient hydraulic fluid in the oil tank.
▶
Check the hydraulic fluid level.
▶
Check for and correct any leakage.
▶
As necessary, refill hydraulic fluid to ensure that
the filling level is between the markings on the
filling level indicator.
Hydraulic power unit is positioned on a
vibrating surface.
▶
Make sure that the hydraulic power unit is
positioned on a secure and non-vibrating surface.
The hydraulic power unit is connected to
the machine via pipelines.
▶
Route out the hydraulic connections between the
hydraulic power unit and the machine with hose lines.
Pressure fluctuations in the
pressure line.
Vibration of the control system, e.g.
pressure controller
.
▶
Check the controller settings and specifically
the parameters of the power amplification in
F3.12 following. For further information, refer to
chapter 7.7 "p/Q PID control" of the Sytronix quick
guide, see chapter 1.2 "Required and amending
documentation".
Incorrect operating
pressure.
Incorrect pressure command value
presetting.
▶
Check and adjust the pressure command value as
applicable.
CytroPac "Basic" and "Advanced" configuration:
▶
Check parameter F1.05.
▶
If only one pressure rating is intended, make sure
that F1.03 and F1.04 are set to 0.
For further information, refer to chapter 7.3
"Pressure value processing" of the Sytronix quick
guide, see chapter 1.2 "Required and amending
documentation".
Excessive pressure loss due to incorrect
dimensioning of hose lines.
▶
Replace the hose lines against larger nominal
widths.
Pressure command value is
not reached or insufficient
flow.
Speed limit too low.
▶
As applicable, change the flow limitation parameter
F1.12. For further information, refer to chapter 7.2
"Flow command value processing" of the Sytronix
quick guide, see chapter 1.2 "Required and
amending documentation".
▶
Observe the maximum admissible speed of
the application (if necessary, contact the
Bosch Rexroth customer service).
Frequency converter
overload during operation.
Drive insufficiently dimensioned.
▶
Check the motor current d0.98 and compare it with
the limit values for continuous load (1.5 kW 4.0 A;
2.2 kW 5.6 A; 3.0 kW 7.4 A; 4.0 kW 9.7 A).
▶
Make sure that the operating point is within the
continuous characteristic curves. For further
information on continuous characteristic curves,
refer to data sheet 51055, see chapter 1.2
"Required and amending documentation".
Frequency converter
overload when
disconnecting hydraulic
actuators.
Pressure relief valve set too high.
▶
Make sure that the pressure relief valve is set 10 %
over the operating pressure.
Generator-based drive effect
(due to rotor inertia).
▶
Extend the delay ramp E0.27
.
Summary of Contents for Rexroth CytroPac
Page 1: ...Operating instructions RE 51055 B 06 17 Replaces English Hydraulic power unit CytroPac ...
Page 6: ...6 84 Bosch Rexroth AG CytroPac RE 51055 B 06 17 ...
Page 76: ...76 84 Appendix Bosch Rexroth AG CytroPac RE 51055 B 06 17 17 2 Declaration of incorporation ...
Page 77: ...Appendix 77 84 CytroPac RE 51055 B 06 17 Bosch Rexroth AG ...
Page 82: ...82 84 Alphabetical index Bosch Rexroth AG CytroPac RE 51055 B 06 17 Notizen ...
Page 83: ...Alphabetical index 83 84 CytroPac RE 51055 B 06 17 Bosch Rexroth AG Notizen ...