12 Motor (continued)
12.3 Configure linear motor continuous current for CKL system
12.3.1 Steps for configuring the linear motor continuous current for CKL system:
1. Double-click parameter S-0-0111 in the parameter list.
2. Input the CKL value (see below table) and then press the Enter key.
System size
Carriage length Primary part
DB value
Factor %
CKL value
CKL 110
180 mm
MCP030B-V180
1.3
75
0.98
240 mm
MCP030C-V180
1.8
75
1.35
300 mm
MCP030D-V180
2.5
75
1.88
CKL 145
244 mm
MCP040C-V300
2.9
85
2.47
364 mm
MCP040E-V300
4.7
85
4.00
484 mm
MCP040G-V300
6.6
85
5.61
CKL 200
237 mm
MCP070C-V300
5.1
82
4.18
297 mm
MCP070D-V300
6.4
82
5.25
417 mm
MCP070F-V300
9.0
82
7.38
3. Parameter S-0-0111 value is now updated in the drive for the specific CKL system size.
4. Close the Parameter editor.
25