F037 300 069 (2015.09.02)
26
Category
Symbol
Min.
Typ.
Max. Unit
Operating temperature range (standard)
Op
- 40
70
°C
Operating temperature range (ATEX)
Op
- 20
70
°C
Storage time
t
Stor
5
years
Storage temperature at
max
60 %
Stor
-40
70
°C
Storage temperature, 2 x 2 h
Stor
-40
85
°C
Humidity
max at 40 °C
95
% r.h.
Humidity
max at 55 °C
65
% r.h.
EMC tests according to DIN EN 61000-6-2 and DIN EN 61000-6-3; EN 61000-4-2/3/4/5/6/8,
EN 55022 B
Vibration test according to IEC 60068-2-6; 2 Hz to 250 Hz at 5 g
Shock test according to IEC 60068-2-27; 20 g half sine 6 ms
Protection IP68 up to 10 bar (depending on cable connection)
Summary of Contents for Rexroth CIMSmart
Page 2: ...F037 300 069 2015 09 02 2 ...
Page 29: ...F037 300 069 2015 09 02 29 ...
Page 33: ...F037 300 069 2015 09 02 33 ...
Page 34: ...F037 300 069 2015 09 02 34 ...
Page 35: ...F037 300 069 2015 09 02 35 ...
Page 36: ...F037 300 069 2015 09 02 36 A 2 F 037 A00 004 CIMS MK IV CIMSMART ATEX VERSION ...
Page 37: ...F037 300 069 2015 09 02 37 ...
Page 38: ...F037 300 069 2015 09 02 38 ...
Page 39: ...F037 300 069 2015 09 02 39 ...
Page 40: ...F037 300 069 2015 09 02 40 Appendix B DRAWING 3 033701 MOUNTING BORE PATTERN ON CYLINDER ...
Page 79: ...F037 300 069 2015 09 02 79 Appendix E DECLARATION OF CONFORMITY EMC DIRECTIVE 2004 108 EC ...
Page 80: ...F037 300 069 2015 09 02 80 Appendix F DECLARATION OF CONFORMITY ATEX DIRECTIVE 94 9 EG ...
Page 81: ...F037 300 069 2015 09 02 81 ...
Page 82: ...F037 300 069 2015 09 02 82 ...
Page 83: ...F037 300 069 2015 09 02 83 ...
Page 84: ......