F037 300 069 (2015.09.02)
11
3.
CIMS
MART
:
F
UNCTION
,
CHARACTERISTICS AND SCOPE OF DELIVERY
3.1.
F
UNCTION
The Cylinder Integrated Measuring System (CIMS) is an integrated displacement measuring
system for use on hydraulic cylinders with an Enduroq 2000 series piston rod coating or the
previous CEC coatings. Grooves underneath the piston rod coating cause a variation in the
magnetic field from the permanent magnet inside the CIMS. The CIMS Hall-effect sensor elements
measure the magnetic field and its variations. Their signals are fed into a micro controller which
calculates the position inside the groove and generates the incremental RS422 output signal. The
sensor and electronics are protected by a robust stainless steel housing, which can be installed
into the head of the cylinder.
Although CIMSmart has a completely new housing in comparison to the previous CIMS Mk II / III
units, sensor and electronics, it is mechanically and electrically compatible with CIMS Mk II / III,
except for the standard connector that changed from a 6-pin connector to a 9-pin connector,
already known from the CIMS Mk IV.
3.2.
C
HARACTERISTICS
CIMSmart features:
High accuracy combined with unlimited stroke lengths.
Sensor integrated in sealing flange, out of the pressure zone of the cylinder.
Easy installation or replacement possible without infringement of the hydraulic integrity of
the cylinder.
Very robust stainless steel housing, protecting the electronics from almost any
environment.
Waterproof, IP68 up to 10bar (depending on output connection type).
Upon request available for potentially explosive atmospheres, ATEX zone 1 certified.
Reliable redundancy possible with multiple CIMS sensors per cylinder.
Contactless operation, no contact between sensor and cylinder rod, no slide pad.
No (manual) calibration necessary, CIMSmart will automatically compensate for mounting
tolerances, magnetic disturbances and temperature effects.
Diagnostic output, gives the possibility to (continuously) retrieve information about sensor
status, sensor identification, current position (since last power on), error codes, etc..
Monitoring output: movement history and stroke length distribution, history of extreme
temperatures and temperature residence time distribution
Summary of Contents for Rexroth CIMSmart
Page 2: ...F037 300 069 2015 09 02 2 ...
Page 29: ...F037 300 069 2015 09 02 29 ...
Page 33: ...F037 300 069 2015 09 02 33 ...
Page 34: ...F037 300 069 2015 09 02 34 ...
Page 35: ...F037 300 069 2015 09 02 35 ...
Page 36: ...F037 300 069 2015 09 02 36 A 2 F 037 A00 004 CIMS MK IV CIMSMART ATEX VERSION ...
Page 37: ...F037 300 069 2015 09 02 37 ...
Page 38: ...F037 300 069 2015 09 02 38 ...
Page 39: ...F037 300 069 2015 09 02 39 ...
Page 40: ...F037 300 069 2015 09 02 40 Appendix B DRAWING 3 033701 MOUNTING BORE PATTERN ON CYLINDER ...
Page 79: ...F037 300 069 2015 09 02 79 Appendix E DECLARATION OF CONFORMITY EMC DIRECTIVE 2004 108 EC ...
Page 80: ...F037 300 069 2015 09 02 80 Appendix F DECLARATION OF CONFORMITY ATEX DIRECTIVE 94 9 EG ...
Page 81: ...F037 300 069 2015 09 02 81 ...
Page 82: ...F037 300 069 2015 09 02 82 ...
Page 83: ...F037 300 069 2015 09 02 83 ...
Page 84: ......