78/84 Appendix
Bosch Rexroth AG
, MIT: HQ 2/G-H, BS 2/G-250, 3 842 564 989/2022-06
17.1.2 Implementation in longitudinal section (TFE 2)
Schema3
S3
Z1
S1
Z4
Z2
S2
558 993-40
S2
S3
S1
S1
S2
S3
1N1
1N2
1N3
1N4
NS Y1
NS
F
T
T
F
T2
D
NS
T2
D
(Z1)
NS Y3 (Z2)
S
Y2 (Z2)
R
Y2 (Z2)
NS Y4
(Z4)
2
1
≥1
558 993-41
Start pulse after end of start-up
Enable cyclic travel
S1
= WT after VE
S2
= WT in position on HQ
S3
= Release secondary section, HQ free
Y1
= Secondary section VE (Z1)
Y2
= HQ up (Z2)
Y3
= HQ down (Z2)
Y4
= Extend DA damper (Z4)
Notes:
• Distance Z1 - Z3 = b
WT
+ 200 mm