Maintenance and repair 55/84
3 842 564 989/2022-06, MIT: HQ 2/G-H, BS 2/G-250,
Bosch Rexroth AG
Re-tensioning of th conveyor chain (HQ 2/C-H)
• Re-tension the conveyor chain 150 hrs after initial commissioning and then every
1000 hrs (see section 10.7.4 "Replacing flat top chain" Fig. 49 on Page 68).
10.3.2 Bearings
The bearings have lifelong lubrication and are maintenance-free under normal
conditions of use.
10.3.3 Gear
The gear is maintenance-free.
10.3.4 Motor
To ensure adequate cooling of the motors, regularly remove dirt and dust deposits:
• From the surface of the motor
• From the intake openings on the fan hood
• From between the cooling ribs
The cleaning intervals depend on the ambient and operating conditions.
10.3.5 LU 2 automatic lubrication unit
The LU 2 automatic lubrication unit lubricates the lift transverse unit chain while in
operation.
The LU 2 automatic lubrication unit consists of the following components:
• LU 2 lubrication unit,
3 842 543 482
• LC 2 oil container,
3 842 543 469
• Adapter kit AS 2/R-300, -700 for HQ 2/C-H,
3 842 543 485
Adapter kit AS 2/C-100, -250 for HQ 2/G-H,
3 842 543 483
10.3.6 LU 2/P automatic lubrication unit
The LU 2/P automatic lubrication unit lubricates the lift transverse unit chain while
in operation.
The LU 2/P automatic lubrication unit consists of the components
• LU 2/P Central lubrication unit,
3 842 562 921
• oil container,
3 842 562 941
• LU 2/P mounting kit,
3 842 562 923
• Adapter kit AS 2/R-300, -700 for HQ 2/C-H,
3 842 543 485
Adapter kit AS 2/C-100, -250 for HQ 2/G-H,
3 842 543 483
EN
GLISH