The following tables illustrate the contact assignment of system connectors -5XG1,-5XG2,
-6XG1,-6XG2 and the S20-AI-4-I module (-5KE1).
Wiring between the system connector and the S20-AI-4-I module is read off per line. For
example, contact -5XG1:2 (PIN2) at system connector -5XG1 is assigned to contact -
5KE1.2XG1:00 (contact 00) at the S20-AI-4 module 5KE1.
Bosch Rexroth recommends using M12 connection lines in compliance with EN 60947-5-2.
This way, any external sensors can be connected according to the wire colors stated in the
following tables.
Wiring of analog inputs between module „-5KE1“ and the M12 socket „-5XG1“.
-5KE1
Contact
Function
Wire color
1)
Contact
-5XG1
-5KE1.1XD1:a1
2)
+24V/U
LS
BN
-5XG1:1
-5KE1.1XD1:b1
2)
GND
BU
-5XG1:3
-5KE1.2XG1:00
I1+ (analog input / current)
WH
-5XG1:2
-5KE1.2XG1:10
2)
I1- (GND)
---
---
---
Reserve
BK
-5XG1:4
---
Reserve
GY
-5XG1:5
---
Coding pin (A-coding) M12 socket
6
3)
1)
The wire colors and connection ID of the M12 socket comply with EN 60947-5-2.
2)
ATTENTION! Wire color deviating from the cable. Connection of this terminal is internally assigned to the terminal strip (IoT 01-1XD100)!
3)
Number „6“ indicates the arrangement of the coding pin of the M12 sockets
Wiring of analog inputs between module „-5KE1“ and the M12 socket „-5XG2“.
-5KE1
Contact
Function
Wire color
1)
Contact
-5XG2
-5KE1.1XD1:a1
2)
+24V/U
LS
BN
-5XG2:1
-5KE1.1XD1:b1
2)
GND
BU
-5XG2:3
-5KE1.2XG1:01
I2+ (analog input / current)
WH
-5XG2:2
-5KE1.2XG1:11
2)
I2- (GND)
---
---
---
Reserve
BK
-5XG2:4
---
Reserve
GY
-5XG2:5
---
Coding pin (A-coding) M12 socket
6
3)
1)
The wire colors and connection ID of the M12 socket comply with EN 60947-5-2.
2)
ATTENTION! Wire color deviating from the cable. Connection of this terminal is internally assigned to the terminal strip (IoT 01-1XD100)!
3)
Number „6“ indicates the arrangement of the coding pin of the M12 sockets
Wiring of analog inputs between module „-5KE1“ and the M12 socket „-6XG1“.
-5KE1
Contact
Function
Wire color
1)
Contact
-6XG1
-5KE1.1XD1:a1
2)
+24V/U
LS
BN
-6XG1:1
-5KE1.1XD1:b1
2)
GND
BU
-6XG1:3
-5KE1.3XG1:02
I3+ (analog input / current)
WH
-6XG1:2
-5KE1.3XG1:12
2)
I3- (GND)
---
---
---
Reserve
BK
-6XG1:4
---
Reserve
GY
-6XG1:5
---
Coding pin (A-coding) M12 socket
6
3)