MKE
10-2
Safety Guidelines for electrical drives
DOK-MOTOR*-MKE*******-PRJ1-EN-E1,44
•
06.97
DANGER
High voltage!
DANGER to life or severe injury!
⇒
Comply with general setup and safety guidelines when
working on high voltage facilities.
⇒
After installation, check the permanent connection of
the protective conductor at all electrical components
for compliance with the terminal diagram.
⇒
Operation, even for quick measuring and testing pur-
poses, is only permitted with permanently attached
protective conductors of all electrical components.
⇒
Prior to accessing electrical parts with voltages grea-
ter than 50 volts, remove them from the mains or the
voltage source. Secure against being switche back
on.
⇒
Wait the discharge time of five minutes after switching
off before accessing the motor.
⇒
Points of electrical connections of the components are
not to be touched when on.
⇒
Before switching the machine on, cover live parts ot
prevent contact.
⇒
Make sure that there is also sufficient against indirect
contact (as per DIN EN 50178/edition11.94, 5.3.2.3).
WARNING
High leakage current!
DANGER to life or severe injury!
⇒
Prior to switching on, connect the electrical devices of
each drive controller, supply unit and the motor with
the protective device to the grounding point.
⇒
The leakage current is greater than 3.5 mA. This
necessitates a permanent connection to the power
supply system (as per DIN EN 50178/edition 11.94,
5.3.2.3).
⇒
Before starting up, even for test purposes, always
connect the protective conductor. High voltages could
otherwise occur on the housing.
10.3 Notes on "safely-isolated low voltages
The connections and interfaces on the drive components intended for
signal voltages range from 5 to 30 volts. These electrical circuits are part
of the safely-isolated electrical circuits (safely-isolated low voltages).
Summary of Contents for R911274804
Page 6: ...MKE IV Contents DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 22: ...MKE 2 12 Mechanical integration into the machine DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 30: ...MKE 3 8 Electrical connections DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 36: ...MKE 4 6 MKE 035 DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 42: ...MKE 5 6 MKE 045 DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 48: ...MKE 6 6 MKE 096 DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 50: ...MKE 7 2 Condition at delivery DOK MOTOR MKE PRJ1 EN E1 44 06 97 ...
Page 69: ...MKE DOK MOTOR MKE PRJ1 EN E1 44 06 97 Service Notes 12 3 Fig 12 2 MKE on DKC ...
Page 70: ...MKE 12 4 Service Notes DOK MOTOR MKE PRJ1 EN E1 44 06 97 Fig 12 3 MKE on HDS HDD ...
Page 75: ......