Dangerous movements caused by plugging
or unplugging plug connectors under load!
DANGER
The plug connectors for the inputs and the outputs must not be connected or
disconnected under load.
8.5.3
Digital input characteristics
Input types
Type 1 acc. to EN 61131-2
Number of inputs
16
Status display by LED
Green
Electrical isolation
Yes (to logic supply)
Reverse voltage protection
yes
Plug-in grid
3.5 (Weidmüller terminal)
Tab. 8-6:
Digital input characteristics
8.5.4
Digital output characteristics
Output types
Semiconductor outputs, non-saving; protected, with automatic
restart, current-carrying
Number of outputs 8
Status display by
LED
Green
Electrical isolation
Yes (to logic supply)
Reverse voltage
protection
Only guaranteed without load connection
Defect of the component caused by
●
Polarity reversal with simultaneous short circuit of the
output lines
●
Polarity reversal with simultaneous connection of exter‐
nally polarized suppressor diodes at the output lines
●
Applying an external voltage > U
Q
Output voltage
Nominal value
24 V
Rated output cur‐
rent
Nominal value:
UL rating:
0.2 A
0.2 A general purpose
5W Tungsten
Simultaneity factor 100 %
Plug-in grid
3.5 (Weidmüller terminal)
Tab. 8-7:
Digital output characteristics
DOK-SUPPL*-VAM*XX.2***-PR03-EN-P
Bosch Rexroth AG
43/69
Rexroth IndraControl VAM 10.2/40.2 Machine Control Panels
Interfaces