40
en | System composition
PRAESENSA
2019.11 | V1.00 |
Installation manual
Bosch Security Systems B.V.
5.4.3
Power consumption
The following table gives an overview of the power demand of the PRAESENSA devices for the
different operating conditions.
Device
Device elements
Power
consumption
[W]
Power from
battery [W]
Current
from
battery [A]
PRA-SCL
System controller
+ per active RJ45 port
3.9
0.4
4.2
0.5
0.35
0.04
PRA-CSLD /
PRA-CSLW
Call station
+ per active RJ45 port
+ per extension PRA-CSE
+ with alarm option
4.2
0.5
0.1
1.2
5.0
0.6
0.1
1.5
0.42
0.05
0.01
0.12
PRA-AD604
Amplifier (sleep)
Amplifier (snooze)
Amplifier (active, idle)
Amplifier (active, low power)
Amplifier (active, full power)
+ per active RJ45 port
6.0
8.0
32
52
220
0.4
6.0
8.5
39
64
250
0.4
0.50
0.71
3.25
5.33
20.83
0.03
PRA-AD608
Amplifier (sleep)
Amplifier (snooze)
Amplifier (active, idle)
Amplifier (active, low power)
Amplifier (active, full power)
+ per active RJ45 port
6.0
8.4
38
70
242
0.4
6.0
9.2
48
88
274
0.4
0.50
0.77
4.00
7.33
22.83
0.03
PRA-ES8P2S
Ethernet switch
+ per active RJ45 port
+ per active SFP port
+ PoE load
7.0
0.4
0.7
load
8.4
0.5
0.8
1.2 x load
0.70
0.04
0.07
0.1 x load
PRA-MPS3
Multifunction power supply
+ per active RJ45 port
+ per active SFP port
5.2
0.4
0.7
5.2
0.4
0.7
0.43
0.03
0.06
Summary of Contents for PRAESENSA