22
| English
Digital laser measure
PLR 25
Laser beam diameter (at 25 °C) approx.
– 10 m distance
9 mm
– 20 m distance
18 mm
Automatic switch-off after approx.
– Laser
20 s
– Measuring tool (without measurement)
5 min
Weight according to EPTA-Procedure 01:2014
0.08 kg
Dimensions
100 x 42 x 22 mm
Batteries
2 x 1.5 V LR03 (AAA)
Battery life approx.
– Individual measurements
10,000
D)
– Continuous measurement
2.5 h
D)
A) For measurements from the rear edge of the measuring tool. The working range increases de-
pending on how well the laser light is reflected from the surface of the target (scattered, not re-
flective) and the brighter the laser point is to the ambient light intensity (interior spaces, twi-
light). For distances of less than 20 m, a retro-reflective target plate should not be used, as it
can lead to measurement errors.
B) For measurements from the rear edge of the measuring tool, 100% reflectivity of the target (e.g.
a white wall), weak backlighting and 25 °C operating temperature. In addition, a deviation influ-
ence of ±0.05 mm/m needs to be taken into account.
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.
D) At an operating temperature of 25 °C
The serial number
(11)
on the type plate is used to clearly identify your measuring tool.
Fitting
Inserting/changing the batteries
It is recommended that you use alkaline manganese batteries to operate the measuring
tool.
Note that if you use 1.2 V batteries, you will not be able to perform as many measure-
ments as you would with 1.5 V batteries.
Push the locking mechanism
(10)
in the direction of the arrow to open the battery com-
partment cover
(9)
and remove the battery compartment cover. Insert the batteries.
1 609 92A 7LM | (29.04.2022)
Bosch Power Tools