English |
21
(16)
Laser target plate
a)
(17)
Protective bag
a)
Accessories shown or described are not included with the product as standard. You can
find the complete selection of accessories in our accessories range.
Display elements
(a)
Indicator for measured value list
(b)
Battery indicator
(c)
Measured value
(d)
Result
(e)
Reference level of measurement
(f)
Laser switched on
(g)
Measuring function
Measuring length
Continuous measurement
Area measurement
Volume measurement
(h) Error
indicator
Technical Data
Digital laser measure
PLR 25
Article number
3 603 F72 5..
Measuring range (typical)
0.05–25 m
A)
Measuring accuracy (typical)
±2.0 mm
B)
Smallest display unit
1 mm
Operating temperature
–10 °C to +40 °C
Storage temperature
–20 °C to +70 °C
Relative air humidity max.
90%
Max. altitude
2000 m
Pollution degree according to IEC 61010-1
2
C)
Laser class
2
Laser type
635 nm, < 1 mW
Bosch Power Tools
1 609 92A 7LM | (29.04.2022)