A. Switch
B. Blue wire
C. Brown wire
D. Terminal
E. Ignition module

Wiring diagram

Robert Bosch Hausgeräte GmbH 

  

CIF: A-28-893550

FD

Gas type
Test point pressure (kPa)

NG

LP

1,0

2,75

Injectors sizes (mm)

            LHF

              

                         LHR

                         RHF

                         RHR

0,90

1,18

0,67

1,18

0,67

0,85

HGC (MJ)
Electrical compliance

AGA approval number
Preinstalled NG

Robert Bosch Hausgeräte GmbH 

CIF: A-28-893550

Gas type

NG

LP

1,0

2,75

              

0,50

HGC (MJ)
Electrical compliance

AGA approval number
Preinstalled NG

In compliance with AS 3100

E-Nr 

 

 

 

 

0,50

            Centre                       

1,70

0,97

1,55

            

LHC

Test point pressure (kPa)

                         

RHC

                         

CF

Injectors sizes (mm)

                         

CR

1,70

1,55

0,85

0,90

0,97

1,18

0,67

In compliance with AS 3100

Made in Spain

Made in Spain

42, 50

38,50

36,00

32,25

7160

7160

19

FD

E-Nr 

PCL755FAU

PCK755FAU

PCI815B90A

Summary of Contents for PCI815B90A

Page 1: ...l Wery Straße 34 81739 München Robert Bosch Hausgeräte GmbH Internet http www bosch hausgeraete de PCL755FAU PCK755FAU This cooktop is for use with Natural Gas and Universal LPG PCI815B90A Cod 9000298631 B ...

Page 2: ...ransportation All the material used for packing is considered essential for this purpose and is also completely recyclable You too can contribut towards protecting the environment by disposing of this material at your nearest recyclable refuse collection point Do not dispose of used cooking oil down the kitchen sink Oil may seriously damage the environment Dispose of it in a closed container at yo...

Page 3: ... connection Gas connection To change injectors Minimum flame adjustment Injector size chart Operating instructions Burner ignition control Burner location User instructions Warnings concerning cooking Cleaning and maintenance Service Trouble shooting Wiring diagram 8 9 9 7 7 6 6 4 4 4 10 11 11 12 12 13 13 Installation procedure 13 Conversion front Nat Gas to Universal LPG 3 19 18 18 17 16 14 ...

Page 4: ...s 2 Do not forget that the unit becomes hot when in use Common sense is important Just because the flame is out does not mean parts cannot still be hot 3 This appliance shall not be used for space heating This instruction is based on safety considerations 4 Be sure to disconnect the electrical supply before disass embly of the appliance 5 Keep the appliance area clear and free from combustible mat...

Page 5: ...orce it Call your official Service Centre immediately for them to repair or replace it 20 The illustrations used in this booklet are only intended as a guide Note To avoid jeopardising the electrical safety of the appliance it is forbidden to use high pressure or steam jet cleaning SHOULD THE RELEVANT CONDITIONS NOT BE PROPERLY SATISFIED THE INSTALLER AND NOT THE MANUFACTURER SHALL HELD LIABLE if ...

Page 6: ...ure test point NAT GAS 95 30 1a 520 min Gas inlet connection min 520 Pressure test point min 150 min 150 Universal LPG Universal LPG This installation must conform with the following Manufacturer s Installation instructions Local Gas Fitting Regulations Municipal Building Codes AGA Installation Code for Gas Burning Appliances S A A Wiring Code Local Electrical Regulations Any other statutory regul...

Page 7: ...l be within 450mm burner A minimum depth of 50mm from the top of the worktop surface must be provided for the appliance 1 For cutout dimensions and clearances refer Fig 1 1a 2 a If the clamps and the selfadhesive seal lower edge of the hob are already fitted depending on the model keeps the entire work surface watertight and prevents spilage from leaking into cupboards underneath Slightly do not u...

Page 8: ... should turn the clips and 4 tighten the screw as shown in Fig 4 that the hob is resting on its entire perimeter 3 Place the hotplate on top of the bench cut out and press down firmly on all edges at the same time to ensure 3 3 8 ...

Page 9: ...f leakage In either of the cases do not move or twist the L tube from its factory set position If for some reason the L tube should be twisted it is necessary to make sure that this area is properly sealed Make sure that The manufacture does not accept any liability for leakage on connections performed by the installer or if the L tube is moved Natural gas connection Pressure test point R 1 2 Pres...

Page 10: ...installed underneath or next to the hotplate The hose should not be subjected to abrasion kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position Unions compatible with the hose fittings must be used and all connections tested for gas leaks The supply connection point shall be accessible with the appliance installed It ...

Page 11: ...ork involved in installation setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply the local gas company Request change over injectors from our customer service deparment refer injector chart below for sizes Coverting the cooktop from Nat Gas to NOTE it is not necessary to adjust the primary air control on these burners 6...

Page 12: ...tion and back a few times screw must be fully tightened down clockwise 6 valve shaft in the event of damage change the entire valve 9 10 1 Turn the control knob to minimum 2 Remove the control knob from the valve spindle 3 4 The adjustment screw is positioned at the rear lower Minimum flame adjustment efit the control knob Never dismount the R Apply pressure with the tip of the screwdriver to rele...

Page 13: ... the ignition procedure described above To turn off the gas supply to a burner turn the control burner Low flame graphic lowest output Burner Position Graphic knob clockwise to the OFF position Refer Fig If ignition fails depress knob and try again If flame is Turn anti clockwise to set the flame to the desired not established in 15 seconds release the control knob and open a door and wait 1 minut...

Page 14: ...top leads to the production of heat and moisture in the kitchen For this reason make sure that the room is properly ventilated Keep natural ventilation mechanical ventilation device e g a range hood or overhead exhaust fan An orangy flame is normal and simply indicates the presence of salt in the atmosphere from cooking If the flame has yellow patches this is not a fault of any kind Boiling burner...

Page 15: ...es Large Steaks omelettes Rice white Steaming burner frying sauce and and ragout vegetables Medium Steaming potatoes Reheating keeping burner fresh vegetables things hot and making stews and pasta tasty casseroles Small Melting and slow caramels cooking butter chocolate vegetables and jelly fruits and Casseroles rice frozen products burner pudding and Defrosting 15 ...

Page 16: ...ff centre They Do not use wide based re ceptacles on the burners nearest to the controls When centred on the bur ner they could touch the controls or raise the tempe rature in the area This may Do not use receptacles with uneven bases They leng then cooking times and in Do not place receptacles on burners off centre They Do not use wide based re ceptacles on the burners nearest to the controls Whe...

Page 17: ...ve pads that may scratch the glass Never use sharp objects such as knives or wire wool to remove the remains of food that has become en crusted onto the surface Grains of sand which may for example come from cleaning vegetables can scratch the glass surface Cleaning and maintenance The high temperatures suffered by the cover on the triple flame burner ring and the stainless steel parts on your hob...

Page 18: ...ed properly Clean the gas ports on the If the gas flow does not seem normal or there is no gas flow The isolation valve is closed If the gas is supplied from a gas bottle it may be empty Open the isolation valve Replace the gas bottle with If the kitchen smells of gas One of the valves has been left open Check to see if a valve has Check that the coupling on the gas bottle is in order What s wrong...

Page 19: ...cal compliance AGA approval number Preinstalled NG Robert Bosch Hausgeräte GmbH CIF A 28 893550 Gas type NG LP 1 0 2 75 0 50 HGC MJ Electrical compliance AGA approval number Preinstalled NG In compliance with AS 3100 E Nr 0 50 Centre 1 70 0 97 1 55 LHC Test point pressure kPa RHC CF Injectors sizes mm CR 1 70 1 55 0 85 0 90 0 97 1 18 0 67 In compliance with AS 3100 Made in Spain Made in Spain 42 5...

Reviews: