background image

5

Gas

During the planning stage, consider the position of supply 

connections.
The cooktop must be connected to the gas supply with 

upstream connection of an isolation valve in accordance with 

the respectively valid regulations. We recommend that the 

isolation valve be fitted prior to the cooktop to enable isolation 

of cooktop from gas supply. The valve must be easily 

accessible at all times.
To find out the factory set gas type, see bottom of cooktop next 

to gas connection.
Remove plastic cap from gas supply line prior to installation.
Fit regulator (N.G.) or a test point (Universal LPG) directly to the 

R 1/2’’ connection.

Direction of gas flow is indicated on the rear of the regulator.
For position of the inlet connection refer 

Preparing to install

:

Use pipe compound or thread sealant, properly theaded pipes 

and careful assembly procedure so that there is no cross 

threading, etc., which might cause damage or leakage.
Make sure that all connections peformed are free of leakage. 

The manufacturer does not accept any liability for leakage on 

connections performed by the installer or if the L-tube is moved 

or twisted.
There are two ways to carry out the connection to the main gas 

line:

The hotplate can be connected with rigid pipe as specified in 

AS/NZS 5601.1

Flexible Hose: If installing with a hose assembly, it must 

comply with AS/NZS 1869, 10 mm ID, class B or D, no more 

than 1.2 m long and installed in accordance with AS/NZS 

5601.1.
Ensure that the hose does not contact the hot surfaces of the 

hotplate, oven, dishwasher or any other appliance that may 

be installed underneath or next to the hotplate. The hose 

should not be subjected to abrasion, kinking or permanent 

deformation and should be able to be inspected along its 

entire length with the cooktop in the installed position. Unions 

compatible with the hose fittings must be used and all 

connections tested for gas leaks.

The supply connection point shall be accessible with the 

appliance installed.
WARNING: Ensure that the hose assembly is restrained from 

accidental contact with the flue outlet of an underbench oven.
Before Leaving- Check all connections for gas leaks with soap 

and water. DO NOT use a naked flame for detecting leaks. 

Ignite all burners both individually and concurrently to ensure 

correct operation of gas valves, burners and ignition. Turn gas 

taps to low flame position and observe stability of the flame for 

each burner individually and all together. Adhere the duplicate 

data plate to an accessible location near the hotplate. When 

satisfied with the hotplate, please instruct the user on the 

correct method of operation. In case the appliance fails to 

operate correctly after all checks have been carried out, refer to 

the authorised service provider in your area.
It should be expressly noted that we cannot accept any liability 

for direct or indirect damage caused by wrong connection, 

leakage or improper installation. When being repaired, the 

appliance must always be disconnected from the mains supply; 

if required, notify our customer service.

Converting the cooktop from Nat. Gas to 

Universal LPG

To change injectors

All work involved in installation, setting and adaptation to a 

different gas type must be carried out by authorised personnel 

from our Service Centre and must comply with current 

regulations and the conditions laid down by the local gas 

company.
Request change-over injectors from our customer service 

deparment (refer injector chart below for sizes).

Before conversion the cooktop must be disconnected from the 

electricity and gas valves must be turned to the OFF position.

Changing the nozzles of the burners on the 

cooktop

1.

Remove the pan supports, burner covers and diffusers.

2.

Change the nozzles using the spanner provided by our 

Service Centre (code 340847, for double and triple flame 

burners code 340808), taking special care to ensure that the 

nozzle does not fall when it is removed from the burner or 

when fitted.
Ensure that it is completely tightened in order to guarantee 

the seal.

Adjustment of the taps

1.

Set the control knobs to minimum.

2.

Remove the control knobs from the taps. It has a flexible 

rubber valve reinforcing ring. Press with the tip of the 

screwdriver to access the tap's adjusting screw.

Never remove the valve reinforcing ring.

 The valve 

reinforcing rings guarantee the watertightness of the 

appliance's interior from liquids and dirt, which might 

otherwise prevent its correct operation.

3.

Adjust the minimum ring setting by turning the by-pass screw 

using a flat head screwdriver.

Natural Gas

Universal LPG

Burner

Hourly Gas 

Consumption 

(MJ)

Injector 

mark

Hourly Gas 

Consumption 

(MJ)

Injector 

mark

Auxiliary

3,60

90

3,50

50

Semi-rapid

6,50

118

6,00

67

Rapid

10,80

155

10,00

85

Wok

12,00

160

11,00

91

Summary of Contents for PBH615B80A

Page 1: ...R INSTRUCTIONS INSTALLATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS GMK10047 This cooktop is for use with Natural Gas and Universal LPG Leave this instructions with the owner PBH615B90A PBH615B80A PBP615A80A ...

Page 2: ...entilation Do not obstruct the flow of combustion and ventilation air Cabinets installed above the gas cooktop must have a minimum clearance of 650 mm 24 The gas pressure regulator supplied with the appliance must be installed in line with the gas pipe N G only For pressure testing in excess of 3 5 kPa 1 2 psig the appliance and its individual shutoff valve must be disconnected from the gas supply...

Page 3: ...ns Preparing to install Refer to AS NZS 5601 1 for piping size details These built in cooktops are intended to be inserted in a benchtop cutout Only an officially authorised technician should connect the appliance Before you begin turn off the gas and electricity supply Before connecting the unit check whether the local connection conditions type of gas are compatible with the unit s setting Obser...

Page 4: ...earest burner to any vertical surface is less than 200 mm the surface shall be protected in accordance with clauses 6 10 1 2 of AS NZS 5601 1 For cutout dimensions and clearances see Preparing to install Installation procedure The adhesive seal provided prevents leaks Adhere it to the work surface around the cut out It must be adhered around the edge of the area cut out Fitting the appliance onto ...

Page 5: ...correct operation of gas valves burners and ignition Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together Adhere the duplicate data plate to an accessible location near the hotplate When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all ch...

Page 6: ...grease splash tray again proceed in the reverse order to removal It is important that all the seals are refitted to form a seal Never remove the tap spindle In the event of a malfunction change the whole tap Operating instructions Burner locations 1 Pan supports 2 Control knobs 3 Auxiliary burner up to 1 kW 4 Semi rapid burner up to 1 75 kW 5 Rapid burner up to 3 kW 6 Double flame wok burner up to...

Page 7: ... risk and does not indicate a malfunction They will disappear in time An orange coloured flame is normal This is caused by the presence of dust in the atmosphere spilt liquids etc If the burner flames are accidentally blown out switch off the burner operating control knob and do not try to relight it for at least 1 minute A few seconds after the burner is switched off a sound thud will be produced...

Page 8: ... high temperatures endured the wok burner and the stainless steel zones grease drip tray burner outline etc can change colour This is normal After each use clean these areas with a product that is suitable for stainless steel It is recommended that the cleaning product available from our Technical Assistance Service code 464524 is used regularly Do not place anything eg flame tamer asbestos mat be...

Page 9: ... The burners are wet Dry the burner caps carefully The burner caps are not correctly positioned Check that the burner caps are correctly posi tioned The appliance is not earthed is poorly connected or the earthing is faulty Contact the installation technician The burner flame is not uni form The burner components are not correctly posi tioned Correctly place the parts on the appropriate burner The...

Page 10: ...10 Wiring diagram A Switch B Blue wire C Brown wire D Terminal E Ignition module ...

Page 11: ...E 9000858156 9000858156 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: