F 002 DG9 A14
2016-07-07
|
Bosch Limited
10 | NTI 105 | Commissioning
en
4.3
Gas selection
¶
Toggle the gas selection switch (Fig. 1, Pos. 3) to
"
Air
" or "
Nitrogen
".
4.3.1
Digital outlet
If the filling hose is connected to the digital outlet
(Fig. 3, Pos. 3), the selected gas (air or nitrogen) pass-
es via the valve block (Fig. 4, Pos. 2) and then to the
vehicle tire. The pressure is monitored by the pressure
sensor and the value is displayed on the LCD.
4.3.2
Direct outlet
If the filling hose is connected to the direct outlet
(Fig. 3, Pos. 4), the selected gas (air or nitrogen) by-
passes the valve block. Hence, the pressure is not moni-
tored by the pressure sensor. The tire pressure has to
be manually checked.
4.4
Accuracy setting
It is possible to control the filling time by setting the
filling accuracy. Higher the accuracy, greater is the fill-
ing time. To set the accuracy rate:
1.
Press
3
in the main menu. Press
2
to select
Accu-
racy
.
2.
Set the accuracy to
1 PSI or
2 PSI.